Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Government Contract opportunity from Department Of Defense was posted on April 1, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

New Building Construction (Administrative & Support Services)

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236220
New
SLED
BEQ- Sanitize & Paint Rooms, B4167, Multi Rooms, MASS1, Station
Solicitation # N400857607511
Solicitation N400857607511 is a task order under MACC contract N4008525D for the remediation, preparation, and painting of 22 barracks rooms and associated bathrooms at MCAS Cherry Point, North Carolina. The contractor is responsible for providing all labor, supplies, and equipment to eradicate active microbial growth using EPA-registered disinfectants and antimicrobial solutions. The scope of work includes preparing approximately 18,562 square feet of barracks room surfaces and 3,840 square feet of bathroom surfaces by removing failed paint and applying a heavy-duty, mold-and-mildew-resistant sealing primer. Final finishing requires a minimum of two coats of specialized mold/mildew-resistant paint that matches the existing color and sheen, ensuring a uniform finish without visible patching or roller marks. The project is estimated between 25,000 and 100,000 dollars, with the award based on the lowest price. All work must be completed within 60 calendar days of the award. Proposals were due by September 16, 2026, and must include a completed price proposal form and a list of subcontractors. Bonding requirements vary by proposal value, with payment bonds required for projects between 35,000 and 150,000 dollars. The contractor must comply with the Buy American Act, the Davis-Bacon Act, and FAR 28.307-2 liability insurance requirements. A qualified Quality Control Manager is required to oversee project standards, and all site cleanup must be completed to return the area to its original condition prior to final acceptance by the Contracting Officer's Representative.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 4 days
NAICS: 236220
New
SLED
DB Construction for HC-130J Flight Simulator Facility at USCG Elizabeth City, NC
Solicitation # 32000479
This design-build project involves the construction of a full motion Weapons System Trainer flight simulator facility for C-130J aircraft at USCG Base Elizabeth City, North Carolina. The approximately 13,000 gross square foot facility will include a simulator bay for a Government Furnish, Government Installed mobile simulator, classrooms, administrative offices, debriefing spaces, and essential support areas for mechanical, electrical, and telecommunications systems. The scope of work extends to site development, including the installation of sidewalks and landscaping, while utilizing existing parking areas. A critical technical requirement is the integration of a Siemens Building Automation System to ensure compatibility with existing installation-wide systems. Issued under the DHS National Multiple Award Construction Contract III, Pool Two, the project has a magnitude estimate of approximately 16 million dollars and a performance period of 719 calendar days. The award is based on a best-value tradeoff selection, weighing price against non-price factors such as planning, organization, communication, and the contractor's specific experience with military or commercial flight simulators. Strict security and compliance protocols are in place, requiring all on-site personnel to be US citizens and necessitating adherence to Davis-Bacon wage determinations, Buy American requirements, and various environmental and historic preservation consultations.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 12 days
NAICS: 236220
New
SLED
Upgrade Life Health Safety Systems in Hangar 250
Solicitation # N400857190530
Solicitation N400857190530, project number 7190530, involves upgrading life health safety systems within Hangar 250 at MCAS Cherry Point in Havelock, North Carolina. The scope of work encompasses architectural improvements, modifications to fire alarm and fire protection systems, and the rerouting of plumbing and electrical systems. Because the work occurs in an occupied facility, the contractor must coordinate closely with base operations and adhere to strict safety and security requirements. The project is estimated to be valued between 1,000,000 and 5,000,000 dollars, with a required completion timeframe of 380 calendar days after the award. The contract will be awarded based on the lowest price. Bidders must submit proposals by September 21, 2026, and those exceeding 150,000 dollars are required to provide bid, payment, and performance bonds. The project is subject to the Davis-Bacon Act and Buy American requirements. Key deliverables include a facility operating plan and manufacturer-provided training information. Administrative requirements include submitting invoices via Wide Area Workflow and providing a detailed schedule of prices within 15 days of the award. Quality control is heavily emphasized, requiring the Contracting Officer's acceptance of a QC plan before any construction work, other than mobilization and surveying, may begin.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 6 days
NAICS: 236220
New
NJCC Bathroom Renovations for Buildings 17 & 18
Solicitation # njcc-bathroom-renovations-buildings-17-18
Education & Training Resources is soliciting bids for a fee-for-service subcontract to perform comprehensive bathroom renovations at the Northlands Job Corps Center in Vergennes, Vermont. The project encompasses the renovation of four bathroom areas in Building 17, totaling approximately 944 square feet, and five bathroom areas in Building 18, totaling approximately 1,260 square feet. The scope of work includes the demolition of existing fixtures and the installation of institutional-grade acrylic shower pans, vitreous China toilets, high-pressure laminate countertops, non-slip porcelain flooring, and LED vanity lighting. To maintain center operations, contractors must utilize a phased sequencing approach, renovating one dormitory at a time. All work must comply with ADA, OSHA, and National Electrical Code standards, and contractors are responsible for the daily off-site disposal of all debris. Bidders may submit a unified proposal for both buildings or standalone bids for each. Proposals must include a completed bid sheet with an itemized cost breakdown separating labor and materials, a detailed project schedule specifying calendar days and working hours, and proof of current Vermont state professional licensing and insurance. The award will not be based solely on the lowest bid, as ETR will evaluate technical alignment with the scope of work to minimize future change orders. Winning bidders must maintain active registration in SAM.gov and provide a Unique Entity ID. The contract incorporates various FAR clauses, including requirements for the Davis-Bacon Act, anti-lobbying certifications, and combating trafficking in persons. Payment terms are net 30 days, contingent upon the submission of a signed punch list and applicable warranties.
Northlands Job Corps Center /ETR

POSTED

about 7 hours ago

DEADLINE

in 1 day

AI Contract Overview

Show more

This contract involves the design and construction of a new administrative building covering 80,074 gross square feet, designated as Building 300. The scope includes full architectural, structural, mechanical, electrical, and plumbing systems, all of which must meet the Department of Veterans Affairs seismic and operational standards. The project is classified under the NAICS code 236220, related to commercial building construction, and is managed by the Department of Defense through the W071 Endist Portland office. The place of performance is indicated by the zip code 97503. The solicitation was posted on April 1, 2026, with a response deadline of June 1, 2026, at 7:00 PM. Although details regarding set-aside types and organization specifics are not provided, this subcontract opportunity is aimed at contractors capable of delivering comprehensive building construction services within the specified standards. The contract ensures compliance with federal guidelines and emphasizes the importance of seismic safety and operational efficiency consistent with VA facility requirements.

General Info

Design and construct 80,074 sq ft VA administrative building meeting seismic and operational standards.

Agency

Department Of Defense → W071 Endist PortlandView Agency

NAICS

236220 - Commercial and Institutional Building ConstructionView NAICS

Place of Performance

OR, 97503

Set-Aside

NONE

Documents

This scope was carved out of W9127N26RA012.

The full solicitation package (4 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

White City Southern Oregon Rehabilitation Center and Clinics (SORCC) Seismic Upgrades

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Portland
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → W071 Endist Portland
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Design and construction of an 80,074 GSF administrative building (B300) with full architectural, structural, and MEP systems, compliant with VA seismic and operational standards.

More opportunities from Department Of Defense → W071 Endist Portland

Same awarding agency

NAICS: 333914
New
Federal
LOP Fire Protection and Unwatering Pump System
Solicitation # W9127N26QA155
Solicitation W9127N26QA155 is a total small business set-aside for the procurement of a fire protection and unwatering pump system for the Lookout Point Powerhouse in Lane County, Oregon. Issued by the Department of Defense W071 Endist Portland, this firm-fixed-price requirement is necessitated by a deep reservoir drawdown that would otherwise disable critical service water and fire protection systems. The scope of work includes the delivery of a 650 GPM vertical pump/motor assembly, a 0.25 HP jockey pump system, a fire pump controller panel, overload protection, and various piping and fitting components. All equipment must meet AWWA E103 and HI 9.1-9.5 standards, with a delivery deadline of March 1, 2027, shipped FOB destination to Lowell, Oregon. The government will award a single purchase order based on an evaluation of technical compliance, past performance, and price, utilizing the HUBZone price evaluation preference. Offerors must be registered in the System for Award Management under NAICS code 333914 and submit a complete quote package via email to the designated point of contact. The solicitation underwent two amendments, with the final response deadline extended to September 11, 2026. Key contractual requirements include compliance with MIL-STD-129 for marking, DFARS cybersecurity and telecommunications regulations, and specific pump acceptance criteria according to HI ANSI/HI 14.6 grade 2B.
Measuring, Dispensing, and Other Pumping Equipment Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 3 days
View Details
NAICS: 334513
New
Federal
Lookout Point DGA supply and incidental install
Solicitation # W9127N26QA160
Solicitation W9127N26QA160 is a total small business set-aside for the purchase and installation of three online Dissolved Gas Analysis (DGA) monitoring systems for the main unit generator step-up transformers at the Lookout Point Powerplant in Jacksonville, Oregon. The contract is a firm-fixed-price award under NAICS code 334513, with the government evaluating quotes based on technical compliance, past performance, and price. The scope of work includes the delivery of the DGA monitors, incidental installation, necessary installation supplies, and eight hours of onsite training conducted by a manufacturer-approved instructor. The systems must be capable of measuring total dissolved combustible gas, total hydrocarbon, oil temperature, moisture-in-oil, ambient temperature, and nine specific gases, while supporting Modbus RTU and DNP3 protocols with RS-232, RS-485, and Ethernet interfaces. Key deliverables include a PC-based software package for remote data analysis and operation and maintenance manuals in both hardcopy and PDF formats. The contractor must provide an onsite field engineer or technician to lead installation, functional testing, and system verification, which must be coordinated with the Contracting Officer at least 14 days in advance. All items and services must be delivered FOB destination by March 1, 2027, with shipments restricted to normal business hours from Monday through Thursday. Additionally, the contractor must comply with specific security requirements, including OPSEC Level I and CUI training for personnel, and adhere to DFARS regulations regarding cybersecurity and the prohibition of covered defense telecommunications equipment.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

2 days ago

DEADLINE

in 9 days
View Details
NAICS: 238220
New
Federal
John Day Dam Powerhouse HVAC Upgrades
Solicitation # W9127N26BA006
The U.S. Army Corps of Engineers Portland District is seeking a single firm-fixed-price contract for comprehensive HVAC upgrades at the John Day Dam Powerhouse, located across Oregon and Washington. The project involves replacing primary and secondary chillers, installing four new chiller skid packages with approximately 600 tons of refrigeration capacity, and implementing a new automated digital HVAC control system. Key technical requirements include a mix of water-cooled and air-cooled systems, new intake and exhaust ducting for fire smoke propagation prevention, and the installation of mini-split units. The work must be performed within an active powerhouse containing high-voltage electrical equipment and areas prone to water intrusion, with a construction period of 1,004 calendar days. The estimated project magnitude is between 25 million and 100 million dollars under NAICS code 238220. A critical condition for award is compliance with Cybersecurity Maturity Model Certification, specifically CMMC Level 2 (Self) for the prime contractor and appropriate levels for subcontractors based on the type of information processed. The solicitation is expected to be issued as an Invitation for Bids in mid-September 2026, requiring bidders to have an active SAM registration and a current NIST SP 800-171 assessment.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

N/A
View Details
NAICS: 333415
New
Federal
Lookout Point Powerhouse Drawdown Transformer Cooling Water Supply
Solicitation # W9127N26QA125
Solicitation W9127N26QA125 is a total small business set-aside for the procurement of a new, FOB destination refrigerated closed-loop water chilling system for the Lookout Point Powerhouse in Lowell, Oregon. The system is required to maintain critical transformer cooling and fire protection during a scheduled reservoir drawdown from October to February that disables the facility's service water. The technical requirements specify a 20-ton (75 kW) system capable of circulating water at 120 gpm and maintaining a maximum cooled water temperature of 80 degrees Fahrenheit in ambient temperatures ranging from -20 to 120 degrees Fahrenheit. Key components include a 3 hp circulating pump, a maintenance tank of at least 100 to 200 gallons depending on configuration, and IP65 rated controls and sensors. The entire system must fit within a 20 by 14 foot horizontal area and include anchor points for concrete seismic anchorage. The contract is managed by the Department of Defense, specifically the Army Corps of Engineers Portland District. All equipment must be standard commercial cataloged products, and the successful contractor is required to provide one hardcopy and one electronic operation and maintenance manual. Delivery is required on or before March 1, 2027, with shipments restricted to Monday through Thursday between 7 am and 3 pm Pacific Time. Evaluation for award is based on technical compliance and past performance. The procurement incorporates various FAR and DFARS clauses, including requirements for System for Award Management registration, Buy American certifications, and specific military standards for marking and labeling such as MIL-STD-130 and MIL-STD-129. Invoicing and reporting must be conducted through the Wide Area WorkFlow system.
Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

POSTED

3 days ago

DEADLINE

in 3 days
View Details
NAICS: 237310
New
Federal
Bonneville Lock and Dam - Navigation Lock 1 Bridge Replacement
Solicitation # W9127N26BA024
Solicitation W9127N26BA024 is a total small business set-aside for the replacement of the Navigation Lock 1 Bridge at the Bonneville Lock and Dam in Cascade Locks, Oregon. The project involves replacing the existing bridge with a new single-span steel girder bridge featuring a concrete deck, two travel lanes, and a sidewalk. The scope includes partial demolition of the existing bridge, construction of approach roadways, and the installation of a concrete stub abutment anchored into rock and a concrete abutment supported by drilled shafts. Due to the requirement that vehicular access remain open throughout construction, the project will likely be executed in phases. Additional technical requirements include lead and asbestos removal, working within environmental and seasonal restrictions, and performing barge crane lifting near high-voltage power lines. The procurement is managed by the USACE Portland District, with a project magnitude estimated between 10 million and 25 million dollars. Following several amendments, the solicitation closing date was extended to October 8, 2026. Bids must be submitted electronically in PDF format to the designated points of contact, as hard copies will not be accepted. Site visit attendees must be U.S. citizens and possess a Real ID for access. The contract includes specific regulatory requirements, such as the use of a professional archaeological monitor during ground disturbance and strict adherence to employment eligibility verification via Form I-9. Foreign contracting parties are subject to a 2 percent Federal excise tax withholding unless specific IRS documentation is provided.
Highway, Street, and Bridge Construction

POSTED

3 days ago

DEADLINE

in 26 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS