Notice of Intent to Sole Source - Bonneville Dam MOPS-30 Transformer Oil Purification System Upgrade
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The U.S. Army Corps of Engineers, Portland District, intends to award a single-source, firm-fixed price contract to High Purity Northwest for the refurbishment and upgrade of a MOPS-30 Transformer Oil Purification System at the Bonneville Lock and Dam. As the original manufacturer, High Purity Northwest will transport the 14-year-old system to their factory to restore it to like-new condition and install four new 16 kW heaters to increase total heating capacity to 128kW. These upgrades are critical to prevent the failure of the unit and ensure the continued reliability of the Main Generator Step-up Transformers. Failure to perform these upgrades could lead to catastrophic equipment failure, costly repairs, potential fatalities, and environmental damage from oil spills near the river. The government plans to solicit the project around September 3, 2026, with a response deadline for capability statements set for September 1, 2026. Interested parties must provide their contact information, CAGE code, and business size category to be considered based on their technical capabilities.
General Info
Agency
NAICS
Place of Performance
Cascade Locks, OR, 97014, USASet-Aside
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Response Deadline
Organization & Contact Information
Full Description
THIS IS A SPECIAL NOTICE PREPARED IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION (FAR) SUBPART 5.2 “SYNOPSES OF PROPOSED CONTRACT ACTIONS”
NAICS: 811310 - Commercial Industrial Machinery Equip Repair
Response Deadline: 1 SEP 2026
The U.S. Army Corps of Engineers (USACE), Portland District (NWP) intends to negotiate/award a firm-fixed price (FFP) service, single source procurement to High Purity Northwest, for the upgrade of an existing MOPS-30 Transformer Oil Purification System to be used for the Bonneville Lock and Dam project.
REASON FOR SOLE SOURCE ACQUISITION:
The statutory authority for this non-competitive acquisition is Revolutionary Far Overhaul RFO Part 12.102(a) Restricting Competition. The purpose of this requirement is for the upgrade of an existing MOPS-30 Transformer Oil Purification System by the system manufacturer, High Purity Northwest Inc. The MOPS-30 system will be delivered to High Purity Northwest’s factory location and refurbished to like new condition. The system will also be upgraded with four (4) new insulated 16 kW heaters bringing the total heating capacity of the system to 128kW, as well as other upgrades listed in the performance work statement.
Background: The existing Mobile Oil Purification System (MOPS-30) owned by USACE, Bonneville Lock and Dam is 14 years old, therefore much of the system's components are entering end-of-service life and need to be replaced to prevent failure of the unit. High Purity Northwest Inc. is the manufacturer of the existing MOPS-30 unit and is the only source that can efficiently and reliably upgrade this system.
Justification: These upgrades will allow Bonneville Lock and Dam to reliably continue use of its existing MOPS-30 unit. The upgrades will also allow the MOPS-30 unit to process larger volumes of oil and move and filter oil using just the outlet pump and new outlet filter.
Impact: The MOPS-30 Transformer Oil Purification System is used to routinely purify the oil in the Main Generator Step-up Transformers (GSUs) at Bonneville Lock and Dam. If the award of this contract is delayed, then maintaining the reliability of the GSU transformers at Bonneville Lock and Dam is also delayed. A potentially harmful or unfavorable condition could occur and possibly lead to a catastrophic failure of the existing MOPS-30 unit and/or the GSU transformer(s). Not only could the repair/replacement and installation of the equipment be costly, but there would be an elevated risk of collateral damage and possible fatalities if the GSU transformers were to fail. Because this equipment is located adjacent to the river, environmental impacts due to an oil spill would also be probable.
The Government intends to solicit to High Purity Northwest directly for this project on or around 3-SEP-2026. At this time, a solicitation does not exist. All responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency.
*NO PHONE INQUIRIES, PLEASE.
CAPABILITY STATEMENT SUBMISSION REQUIREMENTS
(PLEASE REVIEW ALL BELOW)
Point of Contact name, email address and phone number, CAGE code and DUNS number (if available); In the event that the organization is a small business, please state the category of small business, such as 8(a), HUBZone, SDVOSB/VOSB, Women-Owned Small Business.
The Government will evaluate the capabilities of an interested party based on their ability to demonstrate the technical capability and potential performance of this requirement.
Send responses, labeled as “W9127N26Q1CGK – Bonn Transformer Oil Purification System Upgrade,” to the following: