Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on April 20, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

REPLACE MAIN DRY VALVES

Closed
RFISS-167Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
SLED
ICE 8A - Ft Benning Improvements
Solicitation # 70CMSW25R00000011
This firm-fixed-price task order, issued under a MACC multiple-award IDIQ contract by the Department of Homeland Security Immigration and Customs Enforcement, provides design-build services for life, safety, and operational improvements at Fort Benning, Georgia. The project has an estimated magnitude between 4.0 million and 4.5 million dollars and a period of performance not to exceed 365 days from the date of award. The scope of work includes the installation of aluminum awnings at the shipping and receiving dock and Fiske Range, turf replacement at Fiske Range, the demolition and site restoration of Building 2294, gutter and drainage improvements at Building 234, and the replacement and maintenance of commercial HVAC systems across Buildings 2949, 234, 1836, and 19. Additionally, the contractor will perform general facility improvements for Building 301 and the DAGr Team facility. Award will be based solely on the lowest total evaluated price, though the government will also evaluate the offeror's technical approach, design resources, and the validity of their methodology. Proposals must be submitted in two volumes: a technical and safety volume and a pricing volume using the provided CSI division template. The contract is subject to the Davis-Bacon Act, requiring prevailing wage rates and specific paid sick leave provisions. Key administrative requirements include the submission of payment requests via the Invoice Processing Platform accompanied by certified payroll, and the provision of performance and payment bonds. Final inspection and technical assistance will be managed by the Contracting Officer's Representative.
Bristol Alliance of Companies

POSTED

about 9 hours ago

DEADLINE

in 6 days
NAICS: 238220
New
SLED
PIDC Project 3 - Dorm RTU Replacement and SCADA
Solicitation # 872287
This firm-fixed-price task order, issued under an 8(a) MACC IDIQ, involves the replacement and upgrade of Rooftop HVAC Units (RTUs) for the Alpha, Bravo, Charlie, and Delta dorms, as well as a SCADA system upgrade at the Port Isabel Detention Center in Los Fresnos, Texas. The project objective is to replace corroded and obsolete equipment with high-quality, coastal weather-resistant, and durable systems that exceed commercial standards. The scope includes removing existing RTUs, replacing necessary piping, electrical, and ducting, and installing new SCADA software and two chemical feed pumps in compliance with Texas Commission of Environmental Quality standards. The estimated magnitude of the project is between 1.2 million and 1.5 million dollars, with a period of performance of 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. Key requirements include the submission of a Quality Control Plan, a safety plan, and the designation of a Project Manager with at least five years of relevant federal contracting experience. The contractor must also provide a one-year warranty for installation and craftsmanship and ensure all personnel pass required background checks for site access. Compliance with the Davis-Bacon Act and associated executive orders regarding wages and sick leave is mandatory. All payment requests must be submitted electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 9 hours ago

DEADLINE

in 13 days
NAICS: 238220
New
RFQ7593 Smoke Detector Installation
Solicitation # RFQ7593
Management & Training Corporation (MTC) is soliciting bids for a fee-for-service subcontracting opportunity to provide smoke detector installation and fire system services at the Sierra Nevada Job Corps Center in Reno, Nevada. The scope of work requires the replacement of 43 smoke detectors across specific dormitory rooms, including 12 detectors in rooms 11, 15, and 18, 12 detectors in room 19, and 19 detectors in rooms 20 and 21. The contractor must ensure all installed detectors communicate with the fire panel and that all work adheres to NFPA standards and local Authority Having Jurisdiction requirements. Bids must be submitted via email to Tom Williams by 3:00 PM PST on September 18, 2026. To be considered, applicants must provide a completed bid sheet, proof of insurance, and a supplier packet containing a W-9, self-certification form, and acceptance of terms and conditions. This opportunity is open to various small business set-asides, including SDB, WOSB, HUBZone, and Veteran-Owned businesses, under NAICS code 238220. Award decisions will be based on the best value as determined by MTC. The contract mandates compliance with Service Contract Labor Standards and Wage Determination No. 2015-5595 Revision 28 for labor rates in Washoe and Storey counties. Additionally, subcontractors must provide a 12-digit Unique Entity ID and certify their debarment status under FAR 52.209-6 if the subcontract exceeds 30,000 dollars. Strict adherence to government and Department of Labor guidance regarding the protection of sensitive and proprietary information is required.
Sierra Nevada Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
2026-Clearfield-Bldg E8 Welding HVAC
Solicitation # 2026- Clearfield- Welding Bldg. E8 HVAC Replacement
Management & Training Corporation (MTC) is seeking fixed-price lump sum bids for a subcontracting opportunity to replace the 20hp motor connected to the rooftop HVAC system at the Clearfield Job Corps Center in Clearfield, Utah. The scope of work includes the complete removal and replacement of the existing motor, electrical hookup, system testing, commissioning, and the provision of onsite training and maintenance manuals for facility personnel. Bidders must conduct a physical site visit and sign the attendance roster to be eligible for award. The project requires the contractor to handle all permits, fees, and the removal of all construction debris and packaging from the site. Bids are due by September 19, 2026, at 3:00 PM MST and must be submitted via email to the designated points of contact. Submissions must include a signed MTC Bid for Lump Sum Contract form, a detailed cost breakout on company letterhead, and a bid bond guarantee from a surety company with at least an A- rating. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Award decisions will be based on overall best value. The contract is subject to federal regulations, including the Davis-Bacon Act for prevailing wages in Davis County, Utah, and the Contract Work Hours and Safety Standards Act. Compliance with OSHA requirements and federal, state, and local codes is mandatory. Selected contractors must provide a 12-digit Unique Entity ID (UEI) and a 9-digit Tax ID via the MTC Supplier Self-Certification form. Payment will be processed through pay applications using AIA G702 and G703 forms based on a submitted Schedule of Values. Performance and payment bonds must be submitted within five business days of receiving an Intent to Award letter.
Management & Training Corporation

POSTED

about 9 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
CBP7664 Wellness HVAC Compressor Replacement
Solicitation # CBP7664
Management & Training Corporation is seeking bids for a subcontracting opportunity to replace a failed HVAC/refrigeration compressor at the Wellness facility of the Sierra Nevada Job Corps Center in Reno, Nevada. The project is structured in five phases: preparation and environmental safety, demolition and removal, installation of an OEM-specified compressor and related components, system testing and commissioning, and final closeout. The contractor must ensure full restoration of cooling capacity and operational efficiency while adhering to EPA Section 608 regulations for refrigerant recovery. The work must be completed within 30 consecutive business days following a written Notice to Proceed. Bids will be evaluated based on overall best value, considering price, quality, and delivery schedules. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, along with performance and payment bonds from an A-rated surety company. Submission requirements include a signed bid sheet, a detailed bid breakout, and verification of a physical site visit. Contractors must comply with Davis-Bacon Act wage determinations for Washoe County and provide self-certification of their business size and socioeconomic category per FAR 52.219-8. Final payment is contingent upon the submission of a Notice of Final Completion, certified payroll reports, and two sets of operation and maintenance manuals.
Sierra Nevada Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 12 days
NAICS: 238220
New
This is a subcontracting opportunity to replace a chiller in McKinney, TX.
Solicitation # subcontracting-opportunity-replace-chiller-mckinney-tx
Serrato Corporation is seeking bids for a subcontracting opportunity to replace a failing 246-ton air-cooled chiller at the North Texas Job Corps Center, specifically in Building 214/215 located in McKinney, Texas. The scope of work includes the demolition and disposal of the existing unit and the installation and startup of a like-kind, similar model replacement. Additionally, the project requires the installation of a JACE 9000 central integration point for building automation controls to manage the chiller, pumps, boiler, and four multi-zone air handling units. The contractor must also perform cleaning and inspection of the air handling units, replace belts, install four 3-way control valves, and replace three of the four air handler VFDs. Bids must be submitted by September 18, 2026, and quotes must remain valid for 90 days. Required submission documentation includes manufacturer equipment specifications, Form 1413 for Davis-Bacon Act certified payroll compliance for work exceeding 2,000 dollars, and a Certificate of Liability Insurance naming Serrato Corporation as the holder. Insurance minimums include 1 million dollars for Commercial General Liability and Comprehensive Automobile Liability, and 500,000 dollars for Employers Liability. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Primary points of contact for the project are Stacy Smith and Roy Henderson.
Serrato Corporation DBA North Texas Job Corps

POSTED

about 9 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
Main Building 1 Wing 5 – Six Rooftop HVAC Unit Replacement – Glenmont Job Corps Center
Solicitation # S26-010
The Glenmont Job Corps Center is soliciting proposals from qualified, New York State licensed contractors for the replacement and installation of HVAC equipment within Main Building No. 1, Wing 5 (Education Building) in Glenmont, New York. The project involves replacing two 7.5-ton split-system units for the auditorium, one 6-ton rooftop unit for the library and computer lab, and one 12.5-ton rooftop unit for the north and east wing classrooms. Additionally, the scope includes installing four 2-ton ductless mini-split heat pump systems, removing a window air-conditioning unit, and abandoning two 5-ton rooftop units in place. Comprehensive associated work encompasses demolition, roof curbs and penetrations, ductwork, refrigerant and condensate piping, electrical work, controls, structural roof evaluations, and fire alarm and duct smoke detector installations, concluding with testing, balancing, and commissioning. This solicitation is set aside for various small business categories, including SDB, WOSB, HUBZone, and Veteran-Owned Small Businesses. The project must be completed within 210 calendar days following the written Notice to Proceed, and the facility will remain operational throughout the construction period. Key deadlines include a pre-proposal site walkthrough on September 10, 2026, with vendor questions due by September 14, 2026. Final proposals must be submitted by September 21, 2026, at 4:00 PM ET. All work must comply with applicable New York State codes, safety regulations, and environmental requirements.
Adams and Associates, Inc.

POSTED

about 9 hours ago

DEADLINE

in 10 days
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
Adams & Associates, Inc., operating for the U.S. Department of Labor, is soliciting a single lump sum contract to replace HVAC systems at the ABL Dormitory within the Atterbury Job Corps Center in Indiana. The project involves replacing existing R-22 Bryant gas-fired furnaces and condensing units with new 12.5 SEER packaged units utilizing non-R22 refrigerants such as R-410A or R-454B. The scope includes the installation of compatible coils and the reuse of existing electrical disconnects, ductwork, and thermostat wiring. All recovered refrigerant must be labeled and left on-site. Eligible bidders must be registered in SAM.gov with a valid Unique Entity ID and hold a valid Indiana Contractor's License. A mandatory site visit is scheduled for September 23, 2026, with final proposals due by October 5, 2026. Award decisions will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). The contractor must provide a sequenced construction schedule within 10 days of the Notice to Proceed and guarantee all workmanship for one year. Payment terms are Net 30, contingent upon the submission of certified payroll records, a completed SF 1413, and the release of liens. Compliance with EPA, OSHA, and Davis-Bacon Act wage determinations is required.
Adams & Associates, Inc.

POSTED

about 9 hours ago

DEADLINE

in 23 days

General Info

Agency

Department Of Defense → Naval Undersea Warfare CenterView Agency

NAICS

238220 - Plumbing, Heating, and Air-Conditioning ContractorsView NAICS

Place of Performance

WA

Set-Aside

NONE

Documents

(1)

RFISS-167 Replace Main Dry Valves - Industry Questionnaire

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Undersea Warfare Center
Contacts1 person available
OfficeKEYPORT, WA, 98345-7610, USA
Organization / Agency
Department Of Defense → Naval Undersea Warfare Center
View Agency Profile
Office AddressKEYPORT, WA, 98345-7610, USA
Contacts
CPT John P Gathu

Full Description

Show more

Solicitation Number: THERE IS NO SOLICITATION AT THIS TIME


Notice Type: RFI / Sources Sought


Requisition Number: RFISS-167- Replace Main Dry Valves


Synopsis:


The Naval Undersea Warfare Center Division, Keyport is issuing this sources sought notice as a means of conducting market research to identify parties having the resources and interest to perform mechanical and electrical upgrades in a Builidng. The Contractor shall provide all labor, materials, and equipment required to accomplish the following three primary tasks:


 1. Fire Suppression System Repair: Address aging and leaking main dry valves that are causing the fire system compressor to run excessively. The scope includes, but is not limited to, the replacement of the main dry valves.


2.Breathing Air System Upgrade: Demolish the existing breathing air filtration system and replace it with a modern, upgraded system.


3.Electrical and Lighting Work: Install new, adequate lighting over the hot water (HW) tanks. 


This request for capability information does not constitute a Request for Proposal (RFP); submission of any information in response to this announcement is purely voluntary and the Government assumes no financial responsibility for any costs incurred.


Please complete the attached "Questionnaire for Industry" word document attached and return via email to john.p.gathu.mil@us.navy.mil  no later no later than the response date and time identified on this notice.


Attachment[s] a "Questionnaire for Industry" word document.


Pursuant to DFARS 204.75 an approved Cybersecurity Maturity Model Certification (CMMC) of Level X (check for each requirement what level of CMMC is required) is required before a contractor can be considered for award. The contracting team will check each offeror's CMMC level in the Supplier Performance Risk System (SPRS) after offers have been submitted but prior to contract award. Any offerors that are determined not to have an approved CMMC will be ineligible for award. For more information on the CMMC requirement, review the following link: https://www.sprs.csd.disa.mil/cmmc.htm


DO NOT INCLUDE ANY CLASSIFIED, CONTROLLED UNCLASSIFIED, OR ARMS EXPORT CONTROLLED DOCUMENTS OR INFORMATION IN YOUR RESPONSE.


CONTRACTORS ARE REQUIRED TO ADHERE TO OPERATIONS SECURITY (OPSEC) REQUIREMENTS.


EXPLANATION OF THESE REQUIREMENTS IS DETAILED IN SECTION I OF THE OPERATIONS SECURITY GUIDE FOR CONTRACTORS AVAILABLE ONLINE AT: HTTP://WWW.NAVSEA.NAVY.MIL/HOME/WARFARECENTERS/NUWCKEYPORT/RESOURCES.ASPX .


CLICK ON THE OPSEC GUIDE FOR DEFENSE CONTRACTORS UNDER THE RESOURCES TAB.



The Government may not respond to any specific questions or comments submitted in response to this sources sought notice or information provided as a result of this sources sought notice.  Any information submitted by respondents as a result of this sources sought notice is strictly voluntary.  This sources sought notice is for information planning purposes, the Government will not pay or otherwise reimburse respondents for information submitted, and it is not to be construed as a commitment by the Government.


All documentation shall become the property of the Government.  The Government is not soliciting, nor will it accept proposals as a result of this sources sought notice.  All firms responding to this sources sought notice are advised that their response is not a request to be considered for a contract award.  If a solicitation is issued, it will be announced later via the Government-wide point of entry and all interested parties must respond to that solicitation announcement separately from the response to this sources sought notice.  Response to this notice is not a request to be added to a bidders list or to receive a copy of a solicitation.


More opportunities from Department Of Defense → Naval Undersea Warfare Center

Same awarding agency

NAICS: 238210
New
Federal
Building 5945 Electrical Upgrade
Solicitation # N0025326Q0010
The Naval Undersea Warfare Center (NUWC) Division, Keyport is soliciting a firm fixed price contract for an electrical upgrade in Building 5945. The project involves the installation of one 1,200A switchgear and two 600A panels, the relocation of existing metering and electrical equipment, and the reconfiguration of breakers within the existing switchgear. This requirement is a 100% small business set-aside under NAICS code 238210. The period of performance was extended via amendment from 180 to 265 calendar days. All work must comply with the National Electrical Code, EM-385-1-1 safety standards, and Davis-Bacon Act wage determinations for Kitsap County, Washington. Award will be based on a Lowest Price Technically Acceptable (LPTA) analysis. To be considered technically acceptable, offerors must demonstrate at least three years of experience in commercial or industrial applications, provide a detailed work plan, and maintain a stable safety record with acceptable DART and TCR rates. Required submissions include a signed SF 1442, a capability statement, and proof of a Washington State business license, all delivered electronically. The contractor is responsible for providing as-built prints, manufacturer manuals, and necessary system training upon completion. Payment will be processed electronically via Wide Area WorkFlow (WAWF) following the acceptance of all project documentation and punch list items by the government.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 3 days
View Details
NAICS: 238390
New
Federal
Building 206 Lab Upgrade AND Building 233 Breakroom Renovation
Solicitation # N0025326Q0011
The Naval Undersea Warfare Center Division Keyport is soliciting a firm fixed-price construction contract, RFQ N0025326Q0011, for the upgrade of the Building 206 laboratory and the renovation of the Building 233 breakroom and restrooms. The project scope for Building 206 includes asbestos abatement, the installation of Otto Fuel Rated Epoxy Floor Coating, replacement of counters and sinks, and the installation of a new ductless split HVAC unit. The Building 233 project involves the removal and disposal of existing fixtures, cabinets, and plumbing to renovate the breakroom and restrooms, including ensuring ADA compliance. Both projects have a delivery schedule of 270 calendar days from the date of award, with an estimated award date of September 2026. This procurement is a 100% small business set-aside under NAICS code 238390, with an estimated magnitude between $250,000 and $500,000. Award will be based on the Lowest Price Technically Acceptable (LPTA) criteria. To be considered, offerors must pass technical gates requiring at least three years of experience in commercial or industrial applications, an acceptable past performance rating, and acceptable safety ratings based on DART and TCR data from 2021 to 2025. Contractors must provide key personnel, including a Program Manager, Project Manager, Quality Assurance Manager, and a Site Safety and Health Officer with a 30-hour OSHA construction safety certificate. The contract mandates strict adherence to safety, environmental, and operations security (OPSEC) guidelines, including the use of the Wide Area Workflow (WAWF) for monthly invoicing. A detailed Schedule of Values must be submitted within 21 days of award to facilitate progress payments. Bid bonds are required for proposals of $150,000 or more. All proposals must be submitted electronically, and offerors must maintain active registration and certifications in the System for Award Management (SAM).
Other Building Finishing Contractors

POSTED

3 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS