Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Health And Human Services was posted on July 9, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Warranty and Repair Service Support

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract provides a two-year warranty and repair service support for six Midmark dental X-ray units, encompassing preventive maintenance, troubleshooting, and all necessary repair services to ensure uninterrupted operational functionality. This includes routine inspections, part replacements, and technical support to maintain compliance with performance standards throughout the term. Services are expected to be delivered at the place of performance in Sisseton, with all work subject to the contract’s specified timelines and quality requirements. This is a sole-source subcontract under a Total Small Business Set-Aside, classified under NAICS code 811212 for medical and dental equipment repair and maintenance, awarded by the Great Plains Area Indian Health Service under the Department of Health and Human Services. The opportunity was posted on July 9, 2026, with a response deadline of July 24, 2026, and is restricted to small business concerns as defined by the SBA, ensuring economic participation aligns with federal small business goals. The contract does not specify a point of contact, and all inquiries must be directed through the official SAM.gov portal.

General Info

Two-year warranty and repair for six Midmark X-ray units in Sisseton, sole-source small business subcontract.

NAICS

811212 - Computer and Office Machine Repair and Maintenance

Place of Performance

Sisseton, SD, USA

Set-Aside

SBA

Documents

This scope was carved out of IHS1529166.

The full solicitation package (3 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Sisseton Oral Xray

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → Great Plains Area Indian Health Svc
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Provision of 2-year warranty coverage including preventive maintenance, troubleshooting, and repair services for six Midmark dental X-ray units.

More opportunities from Department Of Health And Human Services → Great Plains Area Indian Health Svc

Same awarding agency

NAICS: 339950
Federal
AMENDMENT 1 - Firm Fixed-Price, commercial item, single award, purchase order for a new LED sign at the Woodrow Wilson Keeble Memorial Health Care Center, Sisseton, South Dakota
Solicitation # 75H70626Q00230
The Great Plains Area Indian Health Service is soliciting a firm fixed-price, single-award purchase order for the removal of an existing sign and the installation of a new LED sign at the Woodrow Wilson Keeble Memorial Health Care Center in Sisseton, South Dakota. This procurement is a 100% Small Business Set-Aside under NAICS code 339950. The contractor must provide a Daktronics GT6x-144x216-10-RGB-2V or an approved equal in a two-view, back-to-back configuration. All equipment must be new, and the installation must include structural verification per ASCE 7-22, electrical verification for 120/240 VAC power, and a final inspection by a qualified structural engineer. The period of performance is 120 days from the date of award. Award will be made based on the Lowest Price Technically Acceptable (LPTA) methodology. Proposals are evaluated on four factors: past performance via CPARs, a detailed problem and approach explanation, management capabilities regarding design and installation, and total proposed price. To be eligible, offerors must be rated acceptable in all non-price factors. Required deliverables include a minimum one-year labor and material warranty and documentation of five years of manufacturer parts coverage. All invoices must be processed electronically through the Invoice Processing Platform (IPP). Offers are due by October 30, 2026, at 1:00 pm CST and must be submitted electronically.
Sign Manufacturing

POSTED

7 days ago

DEADLINE

in about 21 hours
View Details
NAICS: 457210
Federal
Sources Sought: Propane Supply Services for the Cheyenne River Health Center, Eagle Butte, SD.
Solicitation # IHS1530962
The Great Plains Area Indian Health Service is conducting market research through Sources Sought Notice IHS1530962 to identify qualified small businesses, specifically Indian Small Businesses Economic Enterprises and Indian Economic Enterprises, capable of providing propane supply services for the Cheyenne River Health Center in Eagle Butte, South Dakota. The objective is to ensure an uninterrupted fuel supply for the facility's dietary department cooking operations and maintenance shop heating system. The anticipated contract will be a firm-fixed-price purchase order with a period of performance of one year from the date of award, falling under NAICS code 457210 for Fuels Dealers. The selected contractor will be responsible for providing all labor, equipment, and transportation to deliver propane, with a strict requirement to complete deliveries within 24 hours of notification. Performance standards include a 100 percent success rate for delivery timelines and full compliance with OSHA, DOT, EPA, and NFPA safety and environmental regulations, including the proper remediation of any spills. Interested parties must submit a capability statement not exceeding 10 pages to the purchasing agent by November 5, 2026, detailing their organizational experience, management capability, and certified small business status. This notice is for planning purposes only and does not constitute a formal solicitation or an obligation to award a contract.
Fuel Dealers

POSTED

8 days ago

DEADLINE

in 7 days
View Details
NAICS: 339112
Federal
High-resolution Autoclavable Camera Heads
Solicitation # IHS-SS-27-1525923
The Indian Health Service Great Plains Area is conducting market research via a sources sought notice to identify qualified vendors capable of providing two high-resolution autoclavable camera heads for the Quentin N. Burdick Memorial Health Care Facility in Belcourt, North Dakota. The required equipment, specifically the Olympus CH-S200-XZ-EA or an equivalent, must be fully compatible and interoperable with the existing Olympus VISERA ELITE II Surgical Imaging System. Technical specifications require the camera heads to feature three CMOS image sensors for Full HD imaging, be fully immersible for cleaning, and be capable of steam sterilization. Additionally, the equipment must meet all U.S. Food and Drug Administration requirements and provide Type BF applied-part protection for electrical safety. This notice is intended for acquisition planning to determine the appropriate procurement strategy and potential set-asides. The government is specifically interested in capabilities from Indian Economic Enterprises, Indian Small Business Economic Enterprises, other small business socioeconomic categories, and existing Federal Supply Schedule or GWAC contract holders. Interested respondents must provide company identification, SAM registration confirmation, and detailed technical specifications of the proposed equipment. Responses are due by October 30, 2026, at 5:00 pm CDT. The anticipated delivery and installation period is 30 to 60 calendar days after the eventual contract award.
Surgical and Medical Instrument Manufacturing

POSTED

13 days ago

DEADLINE

in 1 day
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS