Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

WME-1175 System Technical Support and Monitoring

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)View Agency

NAICS

811210 - Electronic and Precision Equipment Repair and MaintenanceView NAICS

Place of Performance

WV, 25405, USA

Set-Aside

NONE

Documents

This scope was carved out of 36C24526Q0824.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Martinsburg VAMC Water Monitoring

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs remote technical support and system monitoring for the WME-1175 Potable Water Analytics Monitoring System for prime contractors on VA medical center projects. Monitors systems remotely and provides technical support to ensure compliance with VHA Directive 1061. Delivers system uptime reports and technical support resolution.

Similar Contracts

Same NAICS industry code

NAICS: 811210
New
Federal
NSWCCD Emergency repairs, corrective maintenance, preventive maintenance (PM) of TA Instruments equipment
Solicitation # N00167-26-SIMACQ-CD-61-0159
The Naval Surface Warfare Center Carderock Division intends to award a sole source, firm-fixed-price purchase order to Waters Technologies Corporation / TA Instruments for emergency repairs, corrective maintenance, preventive maintenance, and annual calibration of critical laboratory instruments. This urgent requirement follows damage caused by a leak and covers specific equipment including the Waters ACQUITY Arc System, TA Instruments Discovery DMA 850, and TGA 550, along with associated software and chillers. Due to the proprietary nature of the hardware and firmware, the government requires OEM factory-trained and certified service engineers using genuine replacement parts to maintain operational tolerances for NAVSEA fleet programs. While this is a notice of intent for a sole source award under Simplified Acquisition Procedures, other responsible sources may submit capability statements by September 4, 2026. Submissions must be sent to Michael S. Brodie and must demonstrate verifiable OEM authorization, access to proprietary parts, and include company details such as the CAGE code and Unique Entity ID. The procurement is governed by FAR and DFARS regulations, including specific requirements for the System for Award Management and Cybersecurity Maturity Model Certification.
Nswc Carderock

POSTED

about 13 hours ago

DEADLINE

in about 9 hours
View Details
NAICS: 811210
New
Federal
W912P626QA021 Fish Barrier Maintenance and Repair IDIQ
Solicitation # W912P626QA021
Solicitation W912P626QA021 is a Request for Quotation for a four-year, single-award Indefinite Delivery/Indefinite Quantity (IDIQ) contract to provide repair and maintenance services for the Electric Fish Dispersal Barrier System on the Chicago Sanitary and Ship Canal in Romeoville, Illinois. This acquisition is a total set-aside for small business concerns and is being conducted under FAR Part 12 for commercial services. The contract has a minimum value of 5,000 dollars and a maximum value of 3.5 million dollars, with individual task orders ranging from 1,500 dollars to 750,000 dollars. The scope of work requires the contractor to provide all labor, materials, and factory-trained technicians to perform routine preventive maintenance, scheduled overhauls, and emergency repairs. Key technical requirements include monthly, quarterly, and annual inspections of high-voltage pulsers, power distribution panels, backup generators, and cooling arrays, as well as rapid-response troubleshooting within four hours of notification for emergency failures. The contractor must also maintain a quality control program and provide detailed maintenance reports within 10 calendar days of service completion. Award will be based on the most advantageous offer, considering both price and other factors. Proposals must be submitted electronically via the Procurement Integrated Enterprise Environment (PIEE) by September 9, 2026. Key compliance requirements include adherence to the Cybersecurity Maturity Model Certification (CMMC) and Service Contract Act wage determinations for Will County, Illinois. Pricing is structured as firm-fixed-price for routine maintenance, with fully burdened labor-rate ceilings and fixed markups for non-routine repairs.
W072 Endist Chicago

POSTED

about 13 hours ago

DEADLINE

in 6 days
View Details
NAICS: 811210
New
Federal
IM&TE Calibration Services
Solicitation # 80ARC026Q0004
NASA Ames Research Center is soliciting a Firm Fixed Price Blanket Purchase Agreement (BPA) under solicitation 80ARC026Q0004 for the calibration and repair of Inspection, Measuring, and Test Equipment (IM&TE). The contract covers approximately 500 to 900 items annually across various disciplines, including electronics, mechanical, and optical devices. The BPA features a five-year ordering period with performance primarily conducted on-site at Moffett Field, California. Contractors must comply with strict metrology and safety standards, including ISO 9001, ANSI/NCSL Z540.1-1994, ANSI/NCSL Z540.3-2006, and NASA-STD-8739.12A. Additionally, the contractor must adhere to the Service Contract Act for prevailing wage rates and follow comprehensive NASA Ames safety directives regarding electrical safety, hazard communication, and personal protective equipment. The award will be based on a trade-off evaluation where technical capability and past performance are significantly more important than price. Offerors must submit a technical capability statement of no more than five pages, a list of up to three past performances from the last three years, hourly rates for repair and metrology, and proof of required accreditations. All proposals must be submitted electronically to the Contracting Officer by 2:00 p.m. PST on August 31, 2026. The acquisition falls under NAICS code 811210 with a size standard of 34 million dollars. Delivery is required within 30 days after receipt of order on an FOB Destination basis.
NASA Ames Research Center

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811210
New
Federal
Uninterrupted Power Supply (UPS) Maintenance CIWT Pensacola, FL
Solicitation # N6883626Q0046
Solicitation N6883626Q0046 is a firm-fixed-price request for quotes for preventive and corrective maintenance of two Eaton Model 9390-100-120 Uninterrupted Power Supply (UPS) systems located at Building 512, Center for Information Warfare Training (CIWT) Corry Station in Pensacola, Florida. The requirement is a total small business set-aside, specifically targeting women-owned small businesses. The base period of performance runs from October 1, 2026, through March 31, 2027, with four subsequent 12-month option periods. Key deliverables include semi-annual preventive maintenance, a full system battery replacement to be completed within 90 days of award, and 24/7 emergency corrective services with a mandatory 4-hour on-site response time. The government will award the contract based on the Lowest Priced Technically Acceptable (LPTA) method. Offerors must submit a three-volume proposal consisting of price, a technical capability statement limited to 10 pages, and representations and certifications. Technical evaluation focuses on the contractor's ability to perform the Statement of Work and certification that technicians are trained on the specific Eaton UPS models. Maintenance must adhere to manufacturer technical manuals, EM-385, and OSHA safety standards. Invoicing and payment will be processed electronically through the Wide Area WorkFlow (WAWF) system.
Navsup Flc Jacksonville Erp

POSTED

about 13 hours ago

DEADLINE

in 4 days
View Details

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 236220
New
Federal
Z1DA-- Halls and Walls (SECVA) - Construction Project Number 540-26-110
Solicitation # 36C24526B0003
Solicitation 36C24526B0003 is an Invitation for Bids (IFB) issued by the Department of Veterans Affairs for the Halls and Walls construction project (Project Number 540-26-110) at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. This firm fixed price contract is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220, with an estimated project magnitude between 500,000 and 1,000,000 dollars. The scope of work involves general construction, alterations, and the removal of existing structures, specifically focusing on the renovation of finishes in the Emergency Department waiting area, adjacent corridors, and second-floor main corridors and elevator bays. Key deliverables include the installation of luxury vinyl tile flooring, stainless steel corner guards, handrails, and acoustical ceiling systems, with a performance period of 360 calendar days from the Notice to Proceed. The project mandates strict adherence to Infection Control Risk Assessment (ICRA) Class III and above, requiring high-risk work to be performed during overnight or weekend hours to minimize facility disruption. Contractors must provide an OSHA Certified Competent Person on-site and maintain an Experience Modification Rate (EMR) of 1.0 or less. Bidders must submit their offers by September 9, 2026, including a bid guarantee of at least 20 percent of the bid price and a signed Limitations on Subcontracting certification. Award evaluation is based on FAR Part 14 procedures, requiring active SAM registration and verification in the SBA Vet Cert database. Final acceptance is contingent upon the correction of any deficiencies identified by the Contracting Officer's Representative and the submission of final testing, adjusting, and balancing reports for HVAC systems.
Commercial and Institutional Building Construction

POSTED

4 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--SOURCES SOUGHT NOTICE - RENTAL OF UPS - Uninterruptible Power Supply FOR PHONE ROOM LOUIS A JOHNSON VA MEDICAL CENTER 36C24526Q0812
Solicitation # 36C24526Q0812
The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing Sources Sought Notice 36C24526Q0812 to identify qualified contractors for the delivery, installation, start-up, maintenance, and eventual removal of a rental 80 kVA three-phase UPS system at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The scope of work requires the contractor to verify existing connected loads, perform the disassembly and removal of an existing Liebert UPS (Model 37BP080XWXCBNR), and install a temporary unit of comparable size and capacity. The period of performance consists of a twelve-month base year with two unilateral government options to extend the contract for an additional twelve months each. Interested respondents must submit a comprehensive capabilities statement by September 14, 2026, at 10:00 AM ET to Bill Pratt. Required documentation includes business entity details, socio-economic status, SAM.gov Unique Entity ID, and a summary of previous experience with the Veterans Health Administration or similar facilities. Technical requirements are stringent, requiring an electrical license, NFPA 70E certification, OSHA 10/30 training, and specific certifications for the installation and commissioning of Liebert/Vertiv UPS systems. Contractors must also adhere to strict safety protocols, including Lock Out Tag Out procedures, and are responsible for the daily removal of all debris from the facility without using government dumpsters.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

4 days ago

DEADLINE

in 11 days
View Details