WO 1909045 -- CNIC-64 - NRW 1012, Repair Relief Valve on Chiller #2 LOTO chiller relief valve and water. Repair by replacement (1) leaking relief valve and check for proper refrigerant charge. Return Chiller #2 to operational status and perform operations

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac WashingtonView Agency

NAICS

N/A

Place of Performance

W: BETHESDA FSC, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Washington
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Washington
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
♦ Receive and deliver (1) OEM Daikin relief valve. ♦ Mobilize onsite to building 64. ♦ Provide a large tonnage, refrigerant recovery specialist to recover and store refrigerant onsite. Refrigerant will be weighed to determine how much refrigerant has escaped. ♦ Remove failed relief valve and install new OEM valve using proper refrigerant thread sealant and tighten to manufacturer specified torque. ♦ Leak check the repair using dry nitrogen. ♦ Evacuate chiller down to 500 microns of atmosphere or less and perform a vacuum decay test. ♦ If test is passed, introduce the recovered refrigerant charge to the machine. ♦ Any additional required refrigerant will be quoted separately or be supplied by others. ♦ Start and commission chiller #2 and ensure its proper operation. ♦ Provide detailed report of findings to Invicta personnel. ♦ Daikin Factory support can now be scheduled to investigate and diagnose the ongoing issues with the machine. ♦ Clean and remove all debris from work area. ♦ Remove all recovery cylinders from work site. ♦ De-mobilize