Z--Crow Creek Substation Transformer Replacement

Closed
140R6026R0011Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237130
New
Kittrell Job Corps Center-12 Strand Fiber Optic Replacement- Bldg 2, Bldg 3, Bldg 4
Solicitation # kittrell-job-corps-center-12-strand-fiber-optic-replacement-bldg-2-bldg-3-bldg-4
Covenant Learning Solutions, operator of the Kittrell Job Corps Center in North Carolina, is soliciting sealed bids for the replacement of 12-strand aerial fiber optic cables and associated connectors between Buildings 2, 3, and 4. The contractor is responsible for providing all labor, materials, equipment, and supervision to install outdoor-rated fiber optic cable along existing aerial pathways and terminate them into existing network switches. A critical requirement of this project is that the existing network service must remain fully operational without interruption until the owner authorizes the final switch-over. The contractor must also provide a construction timeline for approval during a pre-construction meeting and adhere to standard work hours of 8:00 AM to 3:00 PM, Monday through Friday. The project requires strict adherence to industry standards, local codes, and manufacturer specifications regarding cable support and bend radius. Acceptance is contingent upon successful Optical Loss Testing, OTDR testing, continuity testing, and polarity verification, as well as the submission of a complete closeout package with as-built documentation. Bidders must hold a valid North Carolina General Contractor license and maintain all necessary Builder's Risk and Liability insurance. Proposals must be submitted via email to Rachelle Judkins by September 30, 2026, and must include a completed Mandatory Bid Document. Payment will be issued as a single lump sum upon project completion, provided all required purchasing documentation is submitted.
Covenant Learning Solutions operator of Kittrell Job Corps Center

POSTED

about 14 hours ago

DEADLINE

in 18 days
NAICS: 237130
New
SLED
FTTP-PHASE 4 -IFB 16
Solicitation # IFB 16
Shrewsbury Electric and Cable Operations (SELCO) is soliciting bids for the Fiber to the Premises (FTTP) Network Upgrade Phase 4 in Shrewsbury, Massachusetts. The project involves the installation of approximately 15 miles of single-mode aerial and underground fiber optic cable, including signal transmission and distribution laterals from the existing backbone ring to splitter cabinets and public right-of-way access points. The scope of work encompasses cable installation, splicing, and bi-directional testing, with specific technical requirements for fiber characterization and the use of FieldSmart Fiber Scalability Center equipment. The contract will be awarded to the lowest responsible and eligible bidder, with bids due by September 29, 2026. The project is governed by Massachusetts General Laws, requiring compliance with prevailing wage rates, anti-discrimination statutes, and debarment certifications. Bidders must provide a 5% bid deposit and the selected contractor must furnish a payment bond for 100% of the contract price. Performance is tied to a strict baseline schedule, with full completion, including final deliverables and punch list items, required within 30 weeks of mobilization. SELCO will retain 25% of the total contract value until a final audit and verification of all as-built documentation and testing results are completed. All work must adhere to OSHA safety regulations and local Shrewsbury noise and hour ordinances.
SELCO1 - SELCO

POSTED

1 day ago

DEADLINE

in 17 days

General Info

Agency

Department Of The Interior → Great Plains Regional OfficeView Agency

NAICS

237130 - Power and Communication Line and Related Structures ConstructionView NAICS

Place of Performance

Toston, MT, 59643, USA

Set-Aside

NONE

Documents

(1)

Sources Sought Announcement for Crow Creek Substation Transformer Replacement

PDFsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Interior → Great Plains Regional Office
Contacts1 person available
OfficeBILLINGS, MT, 59101, USA
Organization / Agency
Department Of The Interior → Great Plains Regional Office
View Agency Profile
Office AddressBILLINGS, MT, 59101, USA

Full Description

Show more
Sources Sought Announcement
Crow Creek Substation Transformer Replacement, Canyon Ferry Unit, Pick-Sloan Missouri Basin Program, Montana
THIS NOTICE IS NOT A REQUEST FOR PROPOSAL

General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-06:00) MOUNTAIN DAYLIGHT TIME, DENVER, USA

Classification
Responses Due: 4/27/2026, 3:00 PM MDT
Product Service Code (PSC): Z2NZ, Repair or Alteration of Other Utilities
North American Industry Classification System (NAICS) Code: 237130, Power and Communication Line and Related Structures Construction

Description
This is a Sources Sought announcement for Crow Creek Substation Transformer Replacement, Pick-Sloan Missouri Basin Program, Montana. This announcement is being used for market research and advanced planning purposes. Proposals are not requested and will not be accepted from this Sources Sought Notice. THIS IS NOT A SOLICITATION FOR PROPOSALS AND A CONTRACT WILL NOT BE AWARDED AS A RESULT OF THIS NOTICE.

Work is located at Crow Creek Substation, located in the vicinity of Toston, Montana, off local irrigation district maintenance roads, south of US 287, in Broadwater County, approximately at Latitude: 46° 07'14.79" N, Longitude: 111°26'51.83"W. The substation provides service to Crow Creek Pumping Plant, located on the Missouri River, less than a mile from the substation. The pumping plant operates on a seasonal basis, however the substation is energized year-round providing station-service power to the plant in the off season. Seasonal operation is typically from May to October. The principal components of work that will be completed under this project include the following:

1) Manufacturing and factory testing one (1) step-down transformer.
2) Delivery to and placement of the transformer on existing foundation.
3) Erection of appurtenant equipment including bushings, arrestors, radiators, and filling of insulating oil.
4) Field testing, commissioning, and startup services.

The requirement is to furnish and field test one (1) 2,500 kVA, 65-degree C rise, three-phase, fluid-filled, outdoor, step-down transformer. Low side to be connected in grounded wye and high side connected delta.

Type & Class: Three-phase, sealed tan, outdoor, Class II step-down transformer: KY1A
Capacity and Temp Rise: 2500 kVA, KNAN, 65 Degrees Celsius winding and liquid temperature rise
Frequency: 60 Hertz
High Side: 102 kV with 550kV BIL
Low Side: 4.16 kV with 110kV BIL
Impedance: 8.7% on a 2500 kVA base
Tank Type: Sealed
Winding: Copper
Insulating Fluid: FR3
De-Energized High Tap Changer: +/- 5%, +/-10%
Elevation: 4305 feet above sea level (1312 meters)
Seismic Level: Moderate

Delivery, placement, erection, and startup will occur over a single outage period after the existing transformer has been removed. Erection will include the placement and connection of bushings, arrestors, radiators, and anchoring. Outage will occur between October through April due to seasonal operation of the pumping plant the substation serves.

The Government is seeking responses and capability statements from firms, of any size, who have the specialized knowledge, experience, and resources necessary to successfully complete a project of this size, scope, and complexity. The North American Industry Classification System (NAICS) code is 237130, Power and Communication Line and Related Structures Construction, with a small business size standard of $45 million. The estimated magnitude for this project is between $1,000,000.00 and $5,000,000.

If an interested firm believes it is qualified and capable of performing the work required under this project, please submit a capability statement demonstrating its ability to successfully accomplish the various components of work outlined above.

Responses are requested with the following information:

1) Offerors name, address, UEI number, points of contact with telephone numbers and e-mail addresses.
2) Business size/classification to include any designations as Small Business, HUBZone, Woman Owned Small Business, Service-Disabled Veteran Owned Small Business, Indian Small Business Economic Enterprise or 8(a).
3) Description of capabilities to meet the requirement. Provide any examples of experience with transformers utilizing ester as the insulating fluid and their voltage levels (include all voltage levels).
4) Manufacturer and country of factory to manufacture the transformer. Please supply documentation of the country of manufacture of the transformer(s).
5) Estimated time of delivery from award of contract to delivery at substation.
6) Construction bonding levels, aggregate and per contract.
7) This project may be subject to Executive Order (E.O.) 14063, Use of Project Labor Agreements for Federal Construction Projects, provide examples of any successful implementation and use of a Project Labor Agreement.
8) For Other than Small Businesses (Large Businesses), the ability to meet the Bureau of Reclamations Small Business Subcontracting requirements. The Fiscal Year 2025 Small Business Subcontracting Goals are not yet available. For reference, the Fiscal Year 2025 Small Business Subcontracting Goals were as follows:

SB: 45.87%
SDB: 5.0%
WOSB: 5.0%
SDVOSB: 5.0%
HUBZone: 3.0%
ISBEE: 5.0%

9) If the potential offeror intends to utilize subcontractors for specific work activities, the subcontractor shall demonstrate the subcontractors experience with identified work activities on similar projects. The following information shall be provided for each project: 1) Name and location of project; 2) Description of work; 3) Whether the offeror was the prime contractor, what portion of the work was performed by the offeror, and what portion of the work was performed by subcontractors; 4) Original completion date and actual dates and duration for each project (including modifications); 5) Initial contract amount and final contract amount (including modifications); 6) Name, address, and phone number of CO/owner/COR/point-of-contact who may verify information for the project(s); and, 7) Any problems encountered in performance of the work and corrective actions taken.

The Government will not reimburse any costs associated with responding to this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will not be bound to this information if a solicitation is issued. A determination by the Government not to compete this proposed contract action, based on the responses to this notice, is at the discretion of the Government.

Sources sought responses and capability statements shall be submitted to Sydney Oakes at sydney_oakes@ios.doi.gov and Charlene Maurer charlene_maurer@ios.doi.gov by 3:00 PM MDT on 4/27/2026.

For record keeping purposes, telephonic inquiries will not be accepted.

SYSTEM FOR AWARD MANAGEMENT (SAM)
Effective October 2018, all contractors interested in doing business with the Federal Government must be registered in the System for Award Management (SAM) database at the time they submit their offer. SAM registration and annual confirmation requirements must be accomplished through the SAM website at https://sam.gov/. For assistance with registering in SAM, contact the Federal Services Desk at 1-866-606-8220.

Note: System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations. Examples include 52.222-25, Affirmative Action Compliance, and paragraph (d) of 52.212-3, Offeror Representations and Certifications¿Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.

More opportunities from Department Of The Interior → Great Plains Regional Office

Same awarding agency

NAICS: 335311
Federal
61--UNITROL 6800-Exciter HMI & Firmware Upgrade
Solicitation # 140R6026Q0114
Solicitation 140R6026Q0114 is a request for quotes issued by the Bureau of Reclamation, Missouri Basin Regional Office, for the upgrade of six UNITROL 6800 Exciter Human Machine Interface (HMI) units and associated firmware. The project focuses on replacing obsolete terminals and migrating operating systems from Windows XP/7 to Windows 10 to improve reliability and ensure compliance with cybersecurity and regulatory standards, including NERC-CIP, NIST 800-53, ISA-99, and IEC 62443. The scope includes the procurement of ABB brand-name hardware, such as the ECT Panel Model TPC-1551Tb and specific software licenses, along with certified engineering services for installation, power-up support, and the recommissioning of the exciter to resolve a critical Power System Stabilizer firmware bug. This procurement is a total small business set-aside, requiring offerors to be actively registered in SAM.gov and to provide exact ABB brand-name products to be considered technically acceptable. The period of performance is scheduled from September 1, 2026, to March 1, 2027, with delivery set for March 1, 2027, at the Grand Coulee Dam facility in Washington. Award will be based on a comparative evaluation of technical and price factors to determine the most advantageous offer to the government. Contractors must adhere to strict safety protocols, including Grand Coulee Lockout/Tagout procedures, and utilize the Invoice Processing Platform (IPP) for electronic payments. Following several amendments, the final quote submission deadline was extended to September 14, 2026.
Power, Distribution, and Specialty Transformer Manufacturing

POSTED

16 days ago

DEADLINE

in 2 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS