CONSTRUCTION RM19-0168 B11 REROOF & RENOVATE 2ND & 3RD FLOOR FOR PROJECT SPACE, SIOP, PHNS, JBPHH
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac HawaiiView Agency
NAICS
N/A
Place of Performance
H: CONST CON, USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Hawaii
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
Provide engineering and all relevant planning documents and execute the following projects for Bldg 11: (1) replace roof, (2) repair/replace A/C, and (3) improve 2nd and 3rd floors. This TF-1 consolidates both the existing re-roofing and A/C repairs/replacement projects and an additional project involving the 2nd and 3rd floor renovations. Scope of Work: (1) Replace Roof (Refer to WR 151811; approved CATEX attached) - Replace the existing corrugated metal roofing system, associated flashing, coping, gutters, and downspouts; and install a cool roof system. - Install rigid roof insulation to interior of roof. (see Retro-Commissioning Investigation Report) (2) Repair/Replace A/C (Refer to WR 152048; "Retro-Commissioning Investigation Report for Radiological Control Building [Building 11] Pearl Harbor Naval Shipyard and Intermediate Maintenance Facility [PHNSY&IMF], Hawaii" prepared by AMEL Technologies, Inc. and dated July 10, 2014) - Install a variable frequency drive (VFD) on air-handling unit (AHU)-1. - Install VFDs on AHU-3A and AHU-3B (AHU-3A and AHU-3B were replaced without VFDs in 2015). - Repair structural integrity of outdoor ducts of AHU-1. - Remove exhaust fan and install fresh air ducted fan coil unit to C/105.3 office space. - Replace chilled water piping, chilled water shut-off valve, and three-way valve. - Replace pressure and temperature ports and drain chilled water pipe. - Replace chiller with energy efficient equivalent. - Prepare NEPA documents. (3) Renovate 2nd and 3rd Floors - Renovate office areas of the 2nd and 3rd floors of Bldg 11 for C/300, C/350 SPPG, and/or C/250.3 personnel. - According to C/300, the 2nd floor of Bldg 11 will need ... NOTE: description has been truncated, please see Project Note for full description.
More opportunities from Department Of The Navy → Navfac Hawaii
Same awarding agency
