Hurkey Creek Park Emergency Power Line Replacement Project

Awarded
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Hurkey Creek Park Emergency Power Line Replacement Project is an urgent infrastructure repair initiated by Riverside County Regional Park and Open-Space District to restore electrical service to existing park facilities following the failure of an underground power line. Conducted under emergency provisions, the project qualifies for exemption from full environmental review under California Environmental Quality Act (CEQA) Guidelines Sections 15269 and 15301, which authorize immediate action for repairs that pose risks to public health and safety without expanding existing utility use. All work is performed on-site at 6375 CA-74, Mountain Center, California, with inspection and acceptance occurring at the location of the repair. The project is not subject to federal procurement regulations, as no Federal Acquisition Regulation (FAR) clauses, solicitation numbers, or competitive bidding processes were involved. Instead, it was internally managed by the agency with no formal contract vehicle, pricing details, or award criteria disclosed. The only documentation submitted includes a certified exemption finding and a Notice of Exemption, both required to validate environmental compliance under state law. There are no specified contract types, delivery schedules, FOB terms, invoicing methods, payment offices, or technical specifications beyond the implicit requirement to restore service using standard utility repair practices. The primary point of contact for the project is Gaby Adame, Bureau Chief, reachable via phone or email, serving as the lead agency representative without a formal designation as a contracting officer or technical representative. No socioeconomic certifications, entity identifiers, or contractor representations were required or submitted, as the project was executed directly by the agency under its emergency authority without external contractors or competitive solicitation.

General Info

Emergency power line repair at Hurkey Creek Park, exempt from environmental review, no contract or bidders, agency-led urgent restoration.

Agency

California → Riverside County

NAICS

237130 - Power and Communication Line and Related Structures ConstructionView NAICS

Place of Performance

6375 CA-74, Mountain Center, California, CA

Set-Aside

NONE

Documents

(1)

Notice of Exemption - Turkey Creek Park Emergency Power Line Replacement Project

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

forecast

Awarded

Contract was awarded

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Riverside County
Contacts1 person available
OfficeN/A
Organization / Agency
California → Riverside County
Office AddressN/A
Contacts

Full Description

Show more
Emergency repair and replacement of a failed underground electrical power line at Hurkey Creek Park to restore electrical service to existing park facilities.

Similar Contracts

Same NAICS industry code

NAICS: 237130
New
Keystone Power Outage Repairs
Solicitation # keystone-power-outage-repairs
The Keystone Power Outage Repairs solicitation, issued by Adams and Associates Keystone Red Rock Job Corps, seeks a contractor to perform electrical infrastructure repairs in Drums, Pennsylvania. The project involves restoring electrical service and replacing damaged equipment on poles 35, 43, and 45. Specific technical requirements include the installation of one 75 kva transformer on pole 35, one 100 kva transformer on pole 43, and a bank replacement on pole 45 consisting of one 100 kva and two 50 kva transformers. Additionally, the contractor must install new polymer cutouts and 10kv lightning arresters on poles 35 and 43, implement new service drops to buildings from all three poles, and install a new secondary quadplex for the main trunk line. The scope concludes with the demolition and proper disposal of old secondary cables and the verification of voltage and proper rotation within the buildings. This opportunity is a set-aside for various small business categories, including SDB, WOSB, HUBZone, VOSB, and SDVOSB, under NAICS code 237130. Offerors must be registered and active in SAM.gov and are required to separate labor and materials on their bids. The contract is subject to Davis-Bacon wage standards, and the successful contractor must provide certified payroll. The solicitation was posted on September 3, 2026, with a response deadline of September 9, 2026. Primary point of contact for this effort is Jennie Drumheller.
Adams & Associates Keystone Red Rock Job Corps

POSTED

about 8 hours ago

DEADLINE

in 6 days
View Details