Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

HVAC Installation (Ductless Split Systems)

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This small business set-aside subcontract involves the installation and commissioning of ductless split HVAC systems for prime contractors at the Naval Undersea Warfare Center Division Keyport. The scope of work includes the installation of Energy Star units featuring marine coating packages and UV stabilized line set covers, along with the setup of outside mounting brackets, condensers, weatherproof electrical disconnects, insulation, refrigerant, copper tubing, fan coil units, and condensate drains. The project requires the delivery of a fully operational HVAC system and mandates that all technicians possess at least five years of experience or a journeyman certification. This opportunity is categorized under NAICS code 238220 and is managed by the Department of Defense.

General Info

Small business subcontract for installing ductless split HVAC systems at NUWC Division Keyport.

Agency

Department Of Defense → Naval Undersea Warfare CenterView Agency

NAICS

238220 - Plumbing, Heating, and Air-Conditioning ContractorsView NAICS

Place of Performance

Keyport, WA, 98345, USA

Set-Aside

SBA

Documents

This scope was carved out of N0025326Q0011.

The full solicitation package (17 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Building 206 Lab Upgrade AND Building 233 Breakroom Renovation

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Undersea Warfare Center
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → Naval Undersea Warfare Center
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs and commissions ductless split HVAC units for prime contractors on NUWC Division Keyport projects. Installs outside mounting brackets, condensers, weatherproof electrical disconnects, insulation, refrigerant, copper tubing, fan coil units, and condensate drains. Uses Energy Star units with marine coating packages and UV stabilized line set covers. Requires technicians with minimum 5 years' experience or journeyman certification. Delivers operational HVAC system.

Similar Contracts

Same NAICS industry code

NAICS: 238220
New
SLED
ICE 8A - Ft Benning Improvements
Solicitation # 70CMSW25R00000011
Solicitation 70CMSW25R00000011 is a firm-fixed-price task order issued under an 8(a) Multiple Award Construction Contract (MACC) for design-build services to support the Immigration and Customs Enforcement (ICE) Office of Firearms and Tactical Programs at Fort Benning, Georgia. The project, valued between 4.0 million and 4.5 million dollars, focuses on life, safety, and operational improvements. The scope of work includes the installation of two aluminum awnings at the shipping and receiving dock and Fiske Range Lane 2, turf replacement at Fiske Range, the demolition of Building 2294, gutter and drainage improvements for Building 234, commercial HVAC services and replacements, and general facility improvements for Building 301 and the DAGr Team facility. The period of performance is 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. The contract is subject to the Davis-Bacon Act, requiring prevailing wage rates and specific paid sick leave for workers. Performance and payment bonds are required per FAR 52.228-15. Proposals must be submitted in two volumes: a technical and safety volume and a pricing volume using the provided template. All payment requests must be processed electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
SLED
PIDC Project 3 - Dorm RTU Replacement and SCADA
Solicitation # 872287
This firm-fixed-price task order, issued under an 8(a) MACC IDIQ, involves the replacement and upgrade of Rooftop HVAC Units (RTUs) for the Alpha, Bravo, Charlie, and Delta dorms, as well as a SCADA system upgrade at the Port Isabel Detention Center in Los Fresnos, Texas. The project objective is to replace corroded and obsolete equipment with high-quality, coastal weather-resistant, and durable systems that exceed commercial standards. The scope includes removing existing RTUs, replacing necessary piping, electrical, and ducting, and installing new SCADA software and two chemical feed pumps in compliance with Texas Commission of Environmental Quality standards. The estimated magnitude of the project is between 1.2 million and 1.5 million dollars, with a period of performance of 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. Key requirements include the submission of a Quality Control Plan, a safety plan, and the designation of a Project Manager with at least five years of relevant federal contracting experience. The contractor must also provide a one-year warranty for installation and craftsmanship and ensure all personnel pass required background checks for site access. Compliance with the Davis-Bacon Act and associated executive orders regarding wages and sick leave is mandatory. All payment requests must be submitted electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
RFQ7593 Smoke Detector Installation
Solicitation # RFQ7593
Management & Training Corporation (MTC) is soliciting bids for a fee-for-service subcontracting opportunity to provide smoke detector installation and fire system services at the Sierra Nevada Job Corps Center in Reno, Nevada. The scope of work requires the replacement of 43 smoke detectors across specific dormitory rooms, including 12 detectors in rooms 11, 15, and 18, 12 detectors in room 19, and 19 detectors in rooms 20 and 21. The contractor must ensure all installed detectors communicate with the fire panel and that all work adheres to NFPA standards and local Authority Having Jurisdiction requirements. Bids must be submitted via email to Tom Williams by 3:00 PM PST on September 18, 2026. To be considered, applicants must provide a completed bid sheet, proof of insurance, and a supplier packet containing a W-9, self-certification form, and acceptance of terms and conditions. This opportunity is open to various small business set-asides, including SDB, WOSB, HUBZone, and Veteran-Owned businesses, under NAICS code 238220. Award decisions will be based on the best value as determined by MTC. The contract mandates compliance with Service Contract Labor Standards and Wage Determination No. 2015-5595 Revision 28 for labor rates in Washoe and Storey counties. Additionally, subcontractors must provide a 12-digit Unique Entity ID and certify their debarment status under FAR 52.209-6 if the subcontract exceeds 30,000 dollars. Strict adherence to government and Department of Labor guidance regarding the protection of sensitive and proprietary information is required.
Sierra Nevada Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
2026-Clearfield-Bldg E8 Welding HVAC
Solicitation # 2026- Clearfield- Welding Bldg. E8 HVAC Replacement
Management & Training Corporation is seeking fixed-price lump sum bids for a subcontracting opportunity to replace the HVAC system at Building E8 Welding within the Clearfield Job Corps Center in Clearfield, Utah. The scope of work includes the complete change-out of the existing motor, installation of wiring, conduit, disconnects, breakers, fuses, and starters, and the subsequent validation of voltage, phase, and grounding. Deliverables include startup and testing documentation, onsite training for maintenance personnel, and the provision of manufacturer O&M manuals. All work must adhere to OSHA requirements, federal, state, and local codes, and site safety procedures. Bids must be submitted via email to nelson.dar@jobcorps.org and patricia.willover@mtctrains.com by September 19, 2026, at 3:00 PM MST. To be considered for award based on overall best value, offerors must complete a physical site visit, provide a detailed bid breakout on company letterhead, and submit a bid bond guarantee. The project is a small business set-aside under NAICS 238220 and requires compliance with Davis-Bacon prevailing wage determinations for Davis County. Awardees must provide a UEI number, submit a Schedule of Values for invoicing via AIA G702/G703 forms, and provide original payment and performance bonds from a surety with at least an A- rating within five business days of an Intent to Award letter. Performance dates will be established upon the signing of a Notice to Proceed.
Management & Training Corporation

POSTED

about 7 hours ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
CBP7664 Wellness HVAC Compressor Replacement
Solicitation # CBP7664
Management & Training Corporation is seeking bids for a subcontracting opportunity to replace a failed HVAC/refrigeration compressor at the Wellness facility of the Sierra Nevada Job Corps Center in Reno, Nevada. This fixed-price, single lump sum contract requires the contractor to provide all labor, materials, and equipment to execute a five-phase process including preparation, demolition, installation of an OEM-specified compressor, system testing and commissioning, and final closeout. The project must restore full cooling capacity and operational efficiency while adhering to EPA Section 608 regulations for refrigerant recovery. The work must be completed within thirty consecutive business days following the receipt of a written Notice to Proceed. Bids will be evaluated based on overall best value, considering price, quality, and delivery schedule. The estimated price range is between 0 and 25,000 dollars, though bids equal to or greater than 25,000 dollars require a 20 percent bid bond guarantee and subsequent performance and payment bonds from an A-rated surety company. Submission requirements include a bid sheet, proof of insurance, three comparable project references, and a completed supplier packet containing a W-9 and self-certification of business size under FAR 52.219-8. Contractors must comply with Davis-Bacon Act prevailing wage rates for Washoe County and adhere to FAR 52.204-10 reporting if the award reaches 40,000 dollars. Final payment is contingent upon a successful final inspection and the submission of a notice of final completion, certified payroll reports, and operation and maintenance manuals.
Sierra Nevada Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 11 days
View Details
NAICS: 238220
New
This is a subcontracting opportunity to replace a chiller in McKinney, TX.
Solicitation # subcontracting-opportunity-replace-chiller-mckinney-tx
Serrato Corporation is seeking bids for a subcontracting opportunity to replace a failing air-cooled chiller at the North Texas Job Corps Center, specifically within Building 214/215 in McKinney, Texas. The scope of work includes the demolition and disposal of the existing chiller, the installation and startup of a new air-cooled chiller, and the integration of building automation controls using a JACE 9000 central integration point. Additionally, the contractor is responsible for installing three-way control valves at four air handling units, replacing VFDs, performing AHU cleaning and inspection, and ensuring all wiring is plenum-rated. Bids must be submitted by September 18, 2026, and quotes must remain valid for 90 days. Required submission documentation includes manufacturer equipment specifications, a Certificate of Liability Insurance naming Serrato Corporation as the holder, and Form 1413 for Davis-Bacon Act certified payroll compliance for work exceeding 2,000 dollars. Insurance requirements include a minimum of 500,000 dollars for Employers Liability and 1,000,000 dollars per occurrence for Commercial General Liability. The project is set aside for various small business categories, including SDB, WOSB, HUBZone, VOSB, and SDVOSB. Primary points of contact for this solicitation are Stacy Smith and Roy Henderson.
Serrato Corporation DBA North Texas Job Corps

POSTED

about 7 hours ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Main Building 1 Wing 5 – Six Rooftop HVAC Unit Replacement – Glenmont Job Corps Center
Solicitation # S26-010
The Glenmont Job Corps Center is soliciting proposals from qualified, New York State licensed contractors for the replacement and installation of HVAC equipment within Main Building No. 1, Wing 5 (Education Building) in Glenmont, New York. The project involves replacing two 7.5-ton split-system units for the auditorium, one 6-ton rooftop unit for the library and computer lab, and one 12.5-ton rooftop unit for the north and east wing classrooms. Additionally, the scope includes installing four 2-ton ductless mini-split heat pump systems, removing a window air-conditioning unit, and abandoning two 5-ton rooftop units in place. Comprehensive associated work encompasses demolition, roof curbs and penetrations, ductwork, refrigerant and condensate piping, electrical work, controls, structural roof evaluations, and fire alarm and duct smoke detector installations, concluding with testing, balancing, and commissioning. This solicitation is set aside for various small business categories, including SDB, WOSB, HUBZone, and Veteran-Owned Small Businesses. The project must be completed within 210 calendar days following the written Notice to Proceed, and the facility will remain operational throughout the construction period. Key deadlines include a pre-proposal site walkthrough on September 10, 2026, with vendor questions due by September 14, 2026. Final proposals must be submitted by September 21, 2026, at 4:00 PM ET. All work must comply with applicable New York State codes, safety regulations, and environmental requirements.
Adams and Associates, Inc.

POSTED

about 7 hours ago

DEADLINE

in 9 days
View Details
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
This subcontracting opportunity, managed by Adams & Associates, Inc. for the U.S. Department of Labor, involves the replacement of HVAC systems at the Atterbury Job Corps Center ABL Dormitory in Indiana. The project requires replacing existing R-22 Bryant condensing units and coils serving common areas and dormitory wings A, B, C, and D with new 12.5 SEER packaged units utilizing non-R22 refrigerants such as R-410A or R-454B. The contractor is expected to reuse existing electrical disconnects, ductwork, and thermostat wiring, and must label and leave all recovered refrigerant on-site. Bidders must attend a mandatory site visit on September 23, 2026, and submit a single lump sum proposal by October 5, 2026. Award will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Eligible vendors must maintain an active SAM.gov registration and a Unique Entity ID, hold a valid Indiana Contractor's License, and provide proof of specific automobile and workers' compensation insurance. Compliance with EPA, OSHA, and Davis-Bacon Act wage determinations is mandatory. Final payment is subject to Net 30 terms and is contingent upon the submission of a completed SF 1413, certified payroll records, and the release of liens from all subcontractors and material suppliers.
Adams & Associates, Inc.

POSTED

about 7 hours ago

DEADLINE

in 23 days
View Details

More opportunities from Department Of Defense → Naval Undersea Warfare Center

Same awarding agency

NAICS: 237990
New
Federal
KB Dock Piers Ladder Replacement
Solicitation # N0025326Q0009
The Naval Undersea Warfare Center Division Keyport is soliciting a firm-fixed-price construction contract, designated as RFQ N0025326Q0009, for the replacement of emergency pier ladders at KB Dock in Bangor, Washington, and the Keyport Main Pier in Keyport, Washington. The scope of work involves removing thirteen 20-foot ladder extensions and two upper ladder sections, and installing twelve new 20-foot aluminum ladders and two new upper ladder sections. All new hardware must be constructed from 6061 marine-grade aluminum with nonslip rungs. The estimated magnitude of the requirement is between $100,000 and $250,000, and the project is 100% set aside for small business concerns under NAICS code 237990. Award will be based on the Lowest Price Technically Acceptable (LPTA) method, evaluating technical capability, past performance, and safety records. Offerors must demonstrate at least three years of experience in commercial or industrial applications and provide a stable safety rating based on DART and TCR rates over the last five years. Key requirements include the provision of a Site Safety and Health Officer with a 30-hour OSHA construction safety certification and adherence to EM-385-1-1 safety standards, including the presence of a rescue boat during working hours. Bid bonds are required for proposals of $150,000 or more, and performance and payment bonds must be submitted within ten days of award. All proposals must be submitted digitally, and the contractor must maintain active registration in the System for Award Management.
Other Heavy and Civil Engineering Construction

POSTED

about 23 hours ago

DEADLINE

in 9 days
View Details
NAICS: 333923
New
Federal
Building 514 Crane Rail Cross Bracing Installation
Solicitation # N0025326Q0008
Solicitation N0025326Q0008 is a request for quotation from the Naval Undersea Warfare Center Division Keyport for the installation of crane rail cross bracing at Building 514 in Keyport, Washington. This firm-fixed-price construction requirement is 100 percent set aside for small business concerns under NAICS code 333923. The scope of work includes relocating existing utilities, welding gussets and plate stiffeners, and installing bolted cross bracing. The project is governed by FAR Part 12.1 for commercial items and requires FOB Destination pricing. Offerors must submit digital quotes via email by September 19, 2026, using the provided RFQ forms rather than company quote templates. Requirements for submission include current SAM registration, a safety narrative detailing the offeror's Safety Management System, and a five-year safety data history. The contract imposes strict operational security and safety mandates, including mandatory OPSEC training, adherence to OSHA standards, and compliance with Navy environmental regulations. Personnel must follow rigorous security protocols regarding the use of electronic devices and the handling of sensitive government information. Performance will be tracked via a schedule of values and an installed equipment list to ensure accurate asset reporting and billing.
Overhead Traveling Crane, Hoist, and Monorail System Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 9 days
View Details
NAICS: 238210
New
Federal
Building 5945 Electrical Upgrade
Solicitation # N0025326Q0010
The Naval Undersea Warfare Center (NUWC) Division, Keyport is soliciting a firm fixed price contract for an electrical upgrade in Building 5945. The project involves the installation of one 1,200A switchgear and two 600A panels, the relocation of existing metering and electrical equipment, and the reconfiguration of breakers within the existing switchgear. This requirement is a 100% small business set-aside under NAICS code 238210. The period of performance was extended via amendment from 180 to 265 calendar days. All work must comply with the National Electrical Code, EM-385-1-1 safety standards, and Davis-Bacon Act wage determinations for Kitsap County, Washington. Award will be based on a Lowest Price Technically Acceptable (LPTA) analysis. To be considered technically acceptable, offerors must demonstrate at least three years of experience in commercial or industrial applications, provide a detailed work plan, and maintain a stable safety record with acceptable DART and TCR rates. Required submissions include a signed SF 1442, a capability statement, and proof of a Washington State business license, all delivered electronically. The contractor is responsible for providing as-built prints, manufacturer manuals, and necessary system training upon completion. Payment will be processed electronically via Wide Area WorkFlow (WAWF) following the acceptance of all project documentation and punch list items by the government.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

2 days ago

DEADLINE

in 3 days
View Details
NAICS: 238390
New
Federal
Building 206 Lab Upgrade AND Building 233 Breakroom Renovation
Solicitation # N0025326Q0011
The Naval Undersea Warfare Center Division Keyport is soliciting a firm fixed-price construction contract, RFQ N0025326Q0011, for the upgrade of the Building 206 laboratory and the renovation of the Building 233 breakroom and restrooms. The project scope for Building 206 includes asbestos abatement, the installation of Otto Fuel Rated Epoxy Floor Coating, replacement of counters and sinks, and the installation of a new ductless split HVAC unit. The Building 233 project involves the removal and disposal of existing fixtures, cabinets, and plumbing to renovate the breakroom and restrooms, including ensuring ADA compliance. Both projects have a delivery schedule of 270 calendar days from the date of award, with an estimated award date of September 2026. This procurement is a 100% small business set-aside under NAICS code 238390, with an estimated magnitude between $250,000 and $500,000. Award will be based on the Lowest Price Technically Acceptable (LPTA) criteria. To be considered, offerors must pass technical gates requiring at least three years of experience in commercial or industrial applications, an acceptable past performance rating, and acceptable safety ratings based on DART and TCR data from 2021 to 2025. Contractors must provide key personnel, including a Program Manager, Project Manager, Quality Assurance Manager, and a Site Safety and Health Officer with a 30-hour OSHA construction safety certificate. The contract mandates strict adherence to safety, environmental, and operations security (OPSEC) guidelines, including the use of the Wide Area Workflow (WAWF) for monthly invoicing. A detailed Schedule of Values must be submitted within 21 days of award to facilitate progress payments. Bid bonds are required for proposals of $150,000 or more. All proposals must be submitted electronically, and offerors must maintain active registration and certifications in the System for Award Management (SAM).
Other Building Finishing Contractors

POSTED

3 days ago

DEADLINE

in 3 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS