Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

J041--Replacement of Condenser Water Pump Skid – Chiller Plant

Awarded
36C24826Q0724Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs is conducting market research through a Sources Sought notice to determine the feasibility of awarding a service-disabled veteran-owned small business (SDVOSB) set-aside contract for the replacement of a condenser water pump skid at the Bay Pines VA Healthcare System in Bay Pines, Florida. The project involves removing the existing pump skid and installing a new one to maintain critical condenser water flow for the chiller system that supports the main hospital kitchen’s walk-in refrigeration. All work must be completed within 60 calendar days of receiving the Notice to Proceed, with any extensions requiring written approval from the Contracting Officer. The contractor is responsible for providing all labor, materials, tools, equipment, and expertise, including electrical disconnect and reconnection, laser shaft alignment, hydrostatic or operational leak testing, and full restoration of insulation, paint, and labeling to VA Engineering standards. Compliance with VA, OSHA, ASME, NFPA, and ASHRAE standards is mandatory, with specific requirements for lockout/tagout procedures, electrical safety per NFPA 70E and OSHA 29 CFR 1910 Subpart S, proper handling and disposal of fluids per VA environmental guidelines, infection control risk assessment adherence, and immediate reporting of safety incidents. Work is scheduled during standard hours of 0730 to 1630 Monday through Friday, excluding federal holidays, but weekend or after-hours work may be required at no additional cost to the government if necessary to minimize disruption to critical operations. No government-furnished materials or equipment will be provided, and the contractor must submit comprehensive documentation including manufacturer cut sheets, pump curves, alignment reports, startup and commissioning records, warranty documents, and as-built markups. Final acceptance requires successful system startup, completion of all deliverables, and a signed final inspection report by both the contractor and the VA Point of Contact. The notice is strictly for planning purposes and does not constitute a solicitation or guarantee of future award, with responses due by June 2, 2026, and targeted toward SDVOSB, VOSB, and small business entities under NAICS code 811310.

General Info

Replace condenser water pump skid at Bay Pines VA with SDVOSB, 60-day completion, compliance required.

Contract Value

$42,121

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

FL, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

12

Amendment 0001 to Solicitation 36C24826Q0724

DOCX, High priority: read this first6 pages · amendment
High

Amendment 0002 to RFQ 36C24826Q0724 - Extension of Offer Receipt Date

DOCX, High priority: read this firstamendment
High

Solicitation 36C24826Q0724 Replacement of Condenser Water Pump Skid

DOCX, High priority: read this first35 pages · rfq
High

Solicitation 36C24826Q0724 - Replacement of Condenser Water Pump Skid

DOCX, High priority: read this first3 pages · rfq
High

Award 36C24826P0973 - Replacement of Condenser Water Pump Skid

DOCX, Low priorityaward
Low

Sources Sought for Replacement of Condenser Water Pump Skid - Solicitation 36C24826Q0724

DOCX, Low priority6 pages · sources-sought
Low

IMG_0437.jpeg

JPG

IMG_0438.jpeg

JPG

IMG_0439.jpeg

JPG

IMG_0440.jpeg

JPG

IMG_0441.jpeg

JPG

IMG_0442.jpeg

JPG

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

2 updates
PhaseAwarded
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Jun 19, 2026 to Jun 23, 2026. The notice description changed.

Awarded

Contract was awarded

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Contacts1 person available
OfficeTAMPA, FL, 33637, USA
Office AddressTAMPA, FL, 33637, USA
Contacts
William PenhallegonContracting Officer

Full Description

Show more
Good day, SDVOSB s, VOSB s, SB s This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSB businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete.
Please direct reply in the affirmative via email if you are interested and can provide the required service/product for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 2nd of June, 2026 at 14:00 EST, thanks. Statement of Work (SOW) Project Title: Replacement of Condenser Water Pump Skid Chiller Plant Location: Bay Pines VA Healthcare System, Bay Pines, FL Requesting Service: Facilities Management Service (FMS) Plant Operations
1. Scope The purpose of this Statement of Work (SOW) is to define the requirements for the removal and replacement of an existing condenser water pump skid serving the chiller plant at the Bay Pines VA Healthcare System. This pump circulates condenser water for the chiller and supplies cooling to the walk-in refrigeration system serving the main hospital kitchen. The contractor shall provide all labor, supervision, materials, tools, equipment, and expertise required to complete the project in accordance with applicable VA, OSHA, ASME, NFPA, and ASHRAE standards. The contractor is responsible for abiding by the facility s lockout / tagout (LOTO) and the electrical disconnection and reconnection of the pump motor. 2. Applicable Documents and Standards All work shall conform to the latest editions of the following standards and directives, as applicable to a chiller plant condenser water pump skid replacement, including but not limited to: VA Directives and Handbooks, including applicable VA Engineering Service guidelines for mechanical and HVAC system work. ASME B31.9 Building Services Piping, applicable to the condenser water piping connections associated with this work. OSHA Regulations, including 29 CFR 1910 (General Industry) and 29 CFR 1926 (Construction). OSHA 29 CFR 1910.147, The Control of Hazardous Energy (Lockout / Tagout). OSHA 29 CFR 1910 Subpart S and NFPA 70E for electrical safe work practices. NFPA 70 (National Electrical Code), applicable to the disconnection and reconnection of the pump motor. ASHRAE guidelines for hydronic system design, water treatment compatibility, and HVAC equipment installation. Florida Building Code Mechanical, and applicable Florida and local codes for mechanical work. Manufacturer installation, operation, and maintenance instructions for the new pump skid. 3. Performance Requirements The contractor shall: Coordinate the system shutdown, isolation, and drain-down of the affected condenser water loop with the VA Point of Contact (POC) and Plant Operations Supervisor prior to beginning any work. Perform lockout / tagout (LOTO) for the work, including coordination with the POC and Plant Operations Supervisor on isolation points, and provide a copy of the contractor LOTO procedure for the work upon request. Disconnect and remove the existing condenser water pump and motor skid serving the kitchen walk-in chiller, including associated piping connections necessary to facilitate removal. Furnish and install one (2) new factory-assembled split-case pump and motor skid sized to match the existing service duty (nominally 100 GPM at 155 ft head, 15 HP, with final sizing confirmed by the contractor against the existing nameplate and system requirements). Make all mechanical piping connections, including new gaskets, flanges, isolation valves, suction strainers, and pressure gauges as required for a complete and functional installation. Install vibration isolation, flexible connectors, and concrete pad or skid anchoring as required by the manufacturer and applicable codes. Perform the electrical disconnection of the existing pump motor and the electrical reconnection of the new pump motor, including any required terminations, conductor verification, and overcurrent protection coordination, in accordance with NFPA 70 and NFPA 70E. Perform laser shaft alignment between the pump and motor following installation, and provide alignment documentation to the POC. Notify the POC and Plant Operations Supervisor when the installation is mechanically and electrically complete and the contractor is ready to energize the new pump. The contractor shall not energize the pump without verbal or written concurrence from the POC or Plant Operations Supervisor that it is acceptable to do so. Start pump, check rotation, and re-fill the condenser water loop, vent the system, verify proper operation, and assist in returning the chiller and downstream walk-in cooling system to normal service. Restore all disturbed insulation, paint, and labeling to match existing VA Engineering standards. Remove all debris, replaced equipment, and packaging materials from the site upon completion. 4. Deliverables The contractor shall provide the following to the VA Point of Contact (POC): Manufacturer cut sheets and submittals for the new pump, motor, and skid prior to installation. Pump curve and verification of duty point against system requirements. Contractor lockout / tagout (LOTO) procedure for the work, available upon request. Documentation of electrical reconnection, including verification of phase rotation and motor amperage at operating condition. Laser alignment report. Startup and commissioning report, including verified flow, suction and discharge pressure readings, and motor amperage at operating condition. Manufacturer warranty documentation and any associated maintenance manuals. As-built markup showing the final configuration of the replaced skid and any modified piping. Final inspection report signed by both contractor and POC. 5. Period of Performance The contractor shall complete all work within 60 calendar days from receipt of the Notice to Proceed (NTP). Any extensions must be approved in writing by the Contracting Officer. 6. Place of Performance All work shall be performed in the Chiller Plant at the Bay Pines VA Healthcare System, located at 10000 Bay Pines Blvd., Bay Pines, Florida 33744. 7. Working Hours Normal working hours are 0730 to 1630, Monday through Friday, excluding federal holidays. The actual outage window will be coordinated with the POC to minimize disruption to the kitchen walk-in cooling system; weekend or after-hours work may be required and shall be performed at no additional cost to the Government when driven by operational impact, scheduling, or completion needs. Any work outside normal hours requires prior written approval from the POC and adherence to facility security and access procedures. 8. Government-Furnished Materials and Services No government-furnished materials, equipment, or labor will be provided. The contractor shall provide all required materials, tools, and equipment to perform this project, including all electrical work associated with the disconnection and reconnection of the pump motor. Bay Pines VA Plant Operations will provide reasonable access, system isolation coordination, and operational support during the outage window. 9. Safety and Environmental Requirements The contractor shall comply with all VA safety and environmental requirements, including: Lockout / Tagout (LOTO) procedures performed by the contractor in coordination with the POC and Plant Operations Supervisor. Electrical safe work practices in accordance with NFPA 70E and OSHA 29 CFR 1910 Subpart S, including verification of de-energization prior to electrical work and confirmation of acceptable conditions prior to re-energization. Hot work permits and fire watch as required. Confined space entry procedures, if applicable. Use of appropriate personal protective equipment (PPE), including arc-rated PPE for electrical work as applicable. Proper handling and disposal of condenser water, treatment chemicals, and any displaced fluids in accordance with VA environmental and infection control requirements. Compliance with infection control risk assessment (ICRA) requirements applicable to the work area. The contractor shall immediately report any safety incidents, near misses, or unintended releases to the POC. 10. Quality Control and Inspection The contractor shall maintain a quality control plan to ensure all work meets contract requirements. The VA POC will conduct periodic inspections during the work and at completion. Deficient work shall be corrected at no additional cost to the Government. Hydrostatic or operational leak testing of all new piping connections shall be witnessed by the POC or designee prior to insulation and final acceptance. 11. Final Acceptance Final acceptance of the project will occur upon satisfactory completion of all work, submission of all required deliverables, successful startup and commissioning, and final inspection by VA Engineering Service. The system shall be returned to full operational condition supporting normal condenser water flow to the chiller serving the main hospital kitchen walk-in cooling system.

Similar Contracts

Same NAICS industry code

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 6 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 811310
New
SLED
Roseville Electric Utility – Gas Compressor Maintenance
Solicitation # 07-137
The City of Roseville is soliciting proposals for Gas Compressor Maintenance Services to support the Roseville Energy Park and the Roseville Energy Center and RPEAK. The selected contractor will provide all labor, supervision, technical expertise, specialized tooling, equipment, and materials necessary for both scheduled preventive and corrective maintenance on natural gas compressors, specifically Gas Packagers and Ariel models, and their associated auxiliary systems. The contract is intended to run for an initial term of five years, with services estimated to commence in April or May. This is a prevailing wage project requiring adherence to all fair employment laws, with certified payroll required for contracts exceeding 25,000 dollars. The successful proposer must provide a 100 percent Faithful Performance Bond and a 100 percent Labor and Materials Bond. Proposals are due by December 17, 2026, and must include a Proposer’s Certification, a Non-collusion Declaration, a Levine Act Disclosure Statement, and proof of active registration with the California Secretary of State. Award will be made to the responsible proposer determined to be the most advantageous to the City through a formal evaluation panel process. Invoicing is to be submitted monthly, delineated by task and personnel, with payment terms set at 30 days following receipt of satisfactory services.
City of Roseville

POSTED

about 6 hours ago

DEADLINE

in about 2 months
View Details

More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)

Same awarding agency

NAICS: 621399
New
Federal
Q524--FY27: Perfusionist Services| NFSG
Solicitation # 36C24827Q0013_1
The Department of Veterans Affairs, Network Contracting Office 8, is soliciting quotes for onsite Perfusion and Autotransfusion services to support the Malcom Randall VA Medical Center in Gainesville, Florida. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The requirement specifies a staffing level of five full-time equivalents, comprising four perfusionists and one autotransfusionist, with each position totaling 2,080 hours per year. The contract includes a base year and three subsequent option periods extending through January 6, 2031. Award will be based on a best-value determination where technical qualifications and past performance are significantly more important than price. Evaluation focuses on candidate qualifications, experience, and the contractor's staffing and contingency plans. The contractor must ensure all personnel meet national standards established by the American Board of Cardiovascular Perfusion and comply with strict quality assurance measures, including a requirement for perfusionists to be onsite or within 30 minutes of the facility during all scheduled operating room hours. Administrative requirements include monthly invoicing in arrears via Tungsten Automation and the submission of monthly performance reports by the 10th of each month. The contractor is responsible for providing medical liability insurance and ensuring all personnel undergo proper vetting, credentialing, and blood-borne pathogen training. Compliance with VA cybersecurity directives and HIPAA privacy regulations is mandatory, with strict liability for any breaches of patient confidentiality.
Offices of All Other Miscellaneous Health Practitioners

POSTED

about 10 hours ago

DEADLINE

in 15 days
View Details
NAICS: 339112
New
Federal
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular
Solicitation # 36C24827Q0095
The Department of Veterans Affairs Network Contracting Office 8 is conducting market research through a Sources Sought Notice to identify qualified businesses capable of providing the De Soutter Medical MBC Sternudrive Lite Model MBC 709-Modular or an equal alternative for the VA Caribbean Healthcare System in San Juan, Puerto Rico. This notice is for research purposes only and does not constitute a formal solicitation or an obligation to award a contract. The government has a preference for domestic products that meet or exceed the salient characteristics of the brand-name equipment. The required items include three MBC 709-Modular handpieces, three reciprocating sternum saws, three sternum guards, three oscillating sagittal sternum saws, four large battery packs, and three sterilization systems. Interested businesses must be registered in the System for Award Management and fall under NAICS code 339112 for Surgical and Medical Instrument Manufacturing, which has a size standard of 1,000 employees. To respond, companies must submit a qualifications letter to Darrin Alexander by November 12, 2026, at 13:00 EST. The submission must include the company's name, address, point of contact, UEI code, socio-economic category, and a capability statement with evidence of past or current contracts for similar requirements. Responses must be sent via email with the subject line RFI# 36C24827Q0095 FY 26: MBC Sternudrive LiteTM; Model MBC 709-Modular.
Surgical and Medical Instrument Manufacturing

POSTED

about 10 hours ago

DEADLINE

in 14 days
View Details
NAICS: 236220
New
Federal
5680--FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service
Solicitation # 36c24826r0124
Solicitation 36C24826R0124 is a firm-fixed-price requirements contract issued by the Department of Veterans Affairs Network Contracting Office 8 for the renovation and expansion of the Cardiology service administrative space at the Malcom Randall VA Medical Center in Gainesville, Florida. The project involves approximately 6,000 square feet of construction on the third floor of Building 1, encompassing selective demolition, site preparation, architectural finishes, and comprehensive mechanical, electrical, plumbing, fire protection, and technology systems work. The estimated project magnitude is between 2,000,000 and 5,000,000 dollars, with a base performance period of 540 to 548 calendar days from the Notice to Proceed. This procurement is strictly set aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Award will be determined using a trade-off process where technical factors—including relevant past performance, technical approach, project planning, safety, infection control, quality control, and project schedule—are combined and weighted approximately equal to price. Offerors must submit a bid guarantee of 20 percent of the bid price or 3,000,000 dollars, whichever is less, and provide a current Experience Modification Rate (EMR) of 1.0 or less. Due to the operational hospital environment, strict adherence to ICRA/PCRA controls, safety protocols, and minimal disruption to services is required. The closing date for the receipt of proposals has been extended to November 16, 2026, at 3:00 PM EST.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 18 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS