Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

RFI Solar Powered Shelter Systems

Active
N65236_SNOTE_0002DF02Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Space and Naval Warfare Systems Center Atlantic (SSC-A) issued a Request for Information (RFI) seeking commercially available solar-powered shelter systems to support emergency communications for Afghan security and police forces across twenty-three districts in Afghanistan. Initially targeting six start-up sites with plans to expand to seventeen additional locations, the shelters are intended to house communication equipment requiring continuous 900W power supply with surge capacity and adequate environmental controls to operate reliably 24/7. The shelters must provide protection for standard rack-mounted equipment, incorporate heating, ventilation, and air conditioning (HVAC) capable of withstanding harsh Afghan environments, and be powered entirely by green energy sources such as solar panels, supplemented by backup diesel generators that must have substantial run times without refueling. Considerations include minimal site preparation, secure placement of generators and fuel tanks inside or adjacent to shelter enclosures, and ease of transport using military and commercial shipping standards with dimensions ideally not exceeding that of a 30-foot ISO container. The RFI requests detailed product information from vendors, including administrative data, technical specifications, power consumption, HVAC capacity, solar panel footprint and configuration, battery system details, generator fuel types and run times, as well as documentation and training resources. Emphasis is placed on providing turnkey shelter and power solutions that require no external dependencies aside from grounding rods and cabling. Vendors must assure systems can operate in diverse Afghan climates with half the shelters deployed in Kabul and half in Kandahar. Package configurations should be modular for shipping and installation at widely dispersed locations. Cost proposals, lead times, and maintenance parameters such as mean time to repair and operational availability are also sought. Responses are limited to 10 pages and are due by 7 December 2011; this RFI is for information gathering and planning only and does not constitute a solicitation for contract award.

General Info

SSC-A seeks solar-powered shelters for Afghan emergency communications, requiring 900W power, HVAC, and modular design.

NAICS

221114 - Solar Electric Power Generation

Place of Performance

SC

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Niwc Atlantic
ContactsNo contacts available
OfficeNORTH CHARLESTON, SC, 29419-9022, USA
Office AddressNORTH CHARLESTON, SC, 29419-9022, USA
ContactsNo contact information available

Full Description

Show more
NOTE: The requirements under this RFI replace N65236_SNOTE_0002DE36.Responses are due no later than 1200 [EST], on 7 December 2011. Space and Naval Warfare Systems Center (SPAWAR) - Atlantics (SSC-A) Request for Information (RFI) is for a shelter to house communications equipment to support the Afghanistan security and police forces. SSC-A has been tasked to provide an emergency communication capability for up to twenty - three (23) districts within Afghanistan. The phase one (1) capability is for six (6) INITIAL (start up) sites with an expansion to seventeen (17) sites making it a total of twenty three (23) sites. The intent of this RFI is to obtain COTS product information that can support the power requirements, heating and cooling of electronics, and housing/protection of the electronics year round. This system will need to operate 24 hour x seven days per week (24 x 7). The purpose of this document is to request information for shelter and solar/power product providers to support Afghanistan emergency communication mission. SSC-A will eventually provide sheltered communication systems and services to the Afghan National Security Forces Police and Afghan Local Police (ALP). The Afghan National Police (ANP) and ALP forces were created under the Government of the Islamic Republic of Afghanistans (GIRoA) Ministry of Interior (MoI) in order to protect its citizens. Due to limited traditional communications infrastructure, this communications project will facilitate host country security through services that provide ANP/ALP with a means to complete field police work and contributes to providing law enforcement services to the local populace. SSC-A will be procuring communications equipment separately. Power/space/heating requirements for this equipment are as follows: (1) Vendor will supply equipment racks inside the shelter for mounting communications equipment. Equipment racks must be standard size (19 inches wide, 1.75 inch Rack units) and steel construction. The communications equipment that needs to go in the shelter is approximately 8 rack units high, no more than 24 inches deep. Communications equipment weighs 60 lbs total. (2) Communications equipment requires 900W of continuous power (24/7), 1100W surge. Vendor will supply power via ten receptacles, 240VAC single phase, 50Hz. IEC 320 C13 receptacles may also be used. (3) Communications equipment in the shelter will emit roughly 1300 BTU/hr. For the purpose of this RFI, vendors will assume that half of the communications shelters will be placed in Kabul, and half will be placed in Kandahar. The operating temperature range of the communications equipment is from 10C to 35C. (4) The system will be capable of being powered 100% by green power such as solar. A small backup diesel generator will be provided by the vendor for use when batteries are depleted due to extended inclement weather. The green power system and batteries shall be capable of providing power to the system for 24 hours with no sunlight, assuming a full charge. The generator and fuel tank provided shall be capable of powering the shelter for a minimum of 36 hours without being refueled. (5) Solar panels must be capable of being placed on the ground with little to no site preparation or infrastructure. The recipient of the equipment has no heavy machinery to perform site construction, lay concrete pads, etc. However, for purposes of this RFI, the vendors may assume the ground is level. The solar panels will be placed in a secure location, but may not require more than one (1) acre of land. The entire system, solar panels and shelters, will be placed in a non-shaded area. (6) To minimize risk of theft of power components, vendor is encouraged to use alternative DC voltages for batteries and inverters. To minimize risk of theft of generators, vendor is required to place the generator and fuel tank inside the primary shelter, or in a separate shelter/skid plate that does not allow direct access to controls and components. To minimize fuel consumption and reduce real estate needs, vendor is encouraged to minimize sizing of system HVAC and shelter. (7) Vendor will provide Automatic Transfer Switch to facilitate switching from green power source to diesel generator. AC service must be continuous through load switches to and from the generator. (8) All outdoor equipment such as solar panels must be able to fit in standard ISO containers for shipping. (9) The shelter may be any size up to a thirty foot ISO container. The shelter will not be manned, and no provisions for human occupation are desired. Vendor is encouraged to evaluate smaller than standard size ISO (8 ft wide, 8 ft tall) containers, but also encouraged to minimize cost. (10) Design of shelter must allow/facilitate movement via standard military and commercial shipping methods. (11) HVAC system, generator, and solar panels must be able to work in the harsh environment (especially dust particles) of Afghanistan. (12) Vendor will supply grounding rods and associated cabling. No other external dependencies will exist. (13) Each of the 23 systems will be going to separate district locations eventually, therefore each system must be packaged separately. All information received will be used by the SSC-A Afghanistan Communications product team to support our technical solution for integration purposes. It will not be shared outside the government Communications Product Team and will be utilized to support our technical solution. SSC-A request for information (RFI) is focused on evaluating shelter and power providers to support its mission. This RFI is for a shelter, power supply/distribution, HVAC only as selected by SSC-A. Please include the following with your technical submission: (1) Administrative Information; (2) Technical Submission; (3) Cost information; and (4) Lead time on equipment ordering. Please provide Administrative Information below: Company information (including size of business), main staff point of contact (POC) info, including name, address, phone number, and website link (as available). Whether the company is a product provider, technical consultant, manufacturer, and/or distributor. Please address all items and design drivers below as part of your Technical Submission (include Cost and lead time ordering information): 1. Product name and a brief description (no more than one page per product). 2. Product solution shall require minimum real estate. Provide physical size of system and each component including the shelter. 3. The communications equipment will be integrated into the shelter by the government. Currently our requirements are to provide a green power solution therefore power consumption is considered important. a. Identify total power consumed by the shelter, including HVAC, any power monitoring/control system, etc. b. Power interface options to support ease of communication system integration, such as IEC 320 C13. c. Identify HVAC system capacity and describe how HVAC system will withstand harsh climates. d. Identify number of batteries and DC voltage of battery system. e. Identify number of solar panels required for each site and size of each. Identify total footprint required for solar panel field. f. Identify shipping requirements (for example, a single 20 foot ISO container) for solar equipment and any other equipment going outside such as grounding rods. g. Identify capacity of diesel generator and identify which fuel types are supported. h. Identify size and capacity of diesel tank and estimated run time based on full tank. i. Identify capacity of solar battery bank and estimated equipment run time based on full charge. j. Identify which components will be located inside the shelter and which will be outside. The vendor is encouraged to provide a high level graphic depiction. k. Identify maturity of solar power solution proposed. l. Identify how design of shelter allows movement via standard military and commercial shipping methods m. Identify color(s) of the outside of the shelter. Additional System Design Drivers 4. Operations and Maintenance (O&M) - a. Mean time to Repair; b. Mean time between Failures; c. Operational Availability (Uptime) 5. Solar/Battery Power System documentation and training. a. CONUS technical staff training available (please price separately); b. OEM documentation; 6. Detailed price and/or cost schedules for products should be outlined as followed: a. Product price and bulk price (itemized by component); b. Responders are asked to identify any SSC-A and/or GSA Contract Schedules . The submitted information will be evaluated for inclusion in the Afghanistan Communications System Selection by SSC-A. Consequently, follow-up requests for feedback should not be made through Federal Business Opportunities posting agency. Vendors may be contacted following submission for more detailed product information. Submittals Respondents are requested to address the items above provided by SSC-A. All material is to be provided to SSC-A within 14 calendar days from published date of release (not later than 12:00 [EST] on 7 December 2011). The shelter/power system provider or vendor submission should not exceed 10 pages total. Technical requirement questions can be satisfied by Michael Massenet, Communications Systems Engineer, at contact@example.gov or +1 (555) 000-0000. Respondents are requested to provide feedback in the following format: MS Office Products The information received shall be reviewed to conduct objective, comparative assessments and validation of available equipment and/or systems. This RFI is for information gathering and planning purposes only, and should not be construed as a Request for Proposal (RFP) or solicitation of an offer. The Government DOES NOT intend to award a contract on the basis of this RFI or otherwise pay for the information solicited. A Word document is attached and available at the e-commerce website listed at the bottom of this announcement. E-mail your non-technical contract related questions and submissions to the Contract Specialist, Paula Somers at contact@example.gov.

Similar Contracts

Same NAICS industry code

NAICS: 221114
New
SLED
Rosemary Solar and Energy Storage System Complex
Solicitation # 2024110253
The Rosemary Solar and Energy Storage System Complex project involves the construction, operation, and eventual decommissioning of a 140-megawatt photovoltaic solar and battery energy storage facility in unincorporated Fresno County, California. Spanning approximately 1,172 to 1,212 acres of agricultural land, the project includes three interconnected generation sites, an on-site substation, and a generation-tie line of up to 2 miles connecting to the PG&E Crescent Substation. Additional infrastructure improvements include the reconductoring of 5 linear miles of the PG&E Helm to Crescent 70 kV transmission line and the raising of a portion of the Crescent Switching Station-Schildner 70 kV power line. The project has undergone a comprehensive environmental review process under CEQA, resulting in a Final Environmental Impact Report and a Notice of Determination certifying that the project will not have a significant environmental effect, provided that adopted mitigation measures and monitoring plans are implemented. Key regulatory considerations include the protection of special-status species, such as the Fresno kangaroo rat and blunt-nosed leopard lizard, and compliance with flood control permits and hazardous waste packaging and labeling regulations. The project received approval from the Fresno County Department of Public Works and Planning on May 21, 2026, and from the Westlands Water District on July 21, 2026, with the latter agreeing to provide construction water for up to two years.
Fresno County

POSTED

6 days ago

DEADLINE

N/A
View Details
NAICS: 221114
SLED
Request for Qualifications for Solar, Wind, Battery Storage, Microgrids, and other Clean Energy Technologies
Solicitation # 0000040569
The California Department of General Services is seeking to establish a Qualified Vendors Pool of energy service providers to design, install, operate, and maintain clean-energy systems, including solar, wind, battery storage, and microgrids, on state-owned properties. This initiative utilizes a third-party financing model where selected vendors provide turnkey solutions with no upfront capital requirements from the state. Projects will be governed by long-term Site Lease Agreements and Power Purchase Agreements spanning twenty to twenty-five years, with electricity priced at a fixed rate per kilowatt hour. Qualified vendors will be eligible to bid on subsequent Requests for Proposals for specific installations across a diverse geographic range in California. To qualify for the pool, respondents must pass a comprehensive evaluation on a pass/fail basis, which includes a review of completeness and verification of submitted information. Mandatory requirements include providing evidence of adequate bonding capacity, creditworthiness from recognized rating agencies, and a commitment letter from financing partners. Vendors must hold active California registration and appropriate licensing, such as C-10 Electrical or C-46 Solar licenses, and must comply with the Darfur Contracting Act. Responses, including a Statement of Qualifications and required certifications, must be submitted by December 23, 2026.
California Department of General Services

POSTED

22 days ago

DEADLINE

in about 2 months
View Details

More opportunities from Department Of Defense → Niwc Atlantic

Same awarding agency

NAICS: 541380
New
Federal
Market Survey for E3 Services Support of C6ISR Systems
Solicitation # N65236-26-RFPREQ-LSUBP00080-0002
The Naval Information Warfare Center, Atlantic (NIWC Atlantic) is conducting a market survey for a contract to provide Electromagnetic Environmental Effects (E3) Test, Evaluation, Training, and Range Services in support of C6ISR Systems. The anticipated scope of work includes testing electromagnetic radiation and spectrum effects, supporting the TEMPEST Program and Protected Distribution Systems inspections, and performing environmental testing such as shock, vibration, altitude, and temperature/humidity. The effort is aligned with the Navy's Information Dominance Roadmap for Electromagnetic Spectrum Usage and the Secretary of Defense's Electromagnetic Spectrum Superiority Strategy. The primary place of performance is at NIWC Atlantic, with potential travel to various CONUS and OCONUS locations. The government anticipates a five-year ordering period with an estimated value between 10 million and 50 million dollars, utilizing approximately 15 full-time equivalents per year. The contract is expected to be a firm-fixed price type for labor and calibration, with cost-reimbursement for materials and travel. Key requirements include adherence to IEEE 149 antenna test procedures, strict cybersecurity compliance, and the use of the DoD Wide Area Work Flow for invoicing. Contractors must maintain appropriate facilities, possess PKI client-side authentication capabilities, and comply with DFARS regulations regarding counterfeit electronic parts and government property management. Responses to this market survey are due by November 4, 2026.
Testing Laboratories and Services

POSTED

about 21 hours ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS