Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on February 18, 2014. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

UPS & Battery Cabinet Maintenance

Awarded
HQ0727-14-R-0010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 5 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 10 hours ago

DEADLINE

in about 2 months

AI Contract Overview

Show more

This contract is a request for proposal issued by the Defense Microelectronics Activity for preventative, remedial, emergency, and over-and-above maintenance services for Eaton UPS systems and battery cabinets located in Buildings 1 and 2 at McClellan, California. The requirement is 100 percent set aside for small businesses under NAICS code 811310. The agreement consists of a base period and two option periods, potentially extending performance through February 28, 2017. Payment is structured as firm fixed price for preventative and remedial maintenance, with time and materials used for over-and-above services. The selected contractor must provide qualified technicians with at least five years of experience with large Eaton UPS systems and a California Registered Professional Engineer for design support. Key requirements include a four-hour emergency response time, adherence to NFPA 70E safety standards, and the submission of detailed service reports. Proposals are evaluated based on best value, weighing technical approach and past performance as significantly more important than price. All on-site personnel must be US citizens and pass a background check to access the facility.

General Info

Contract Value

$130,632.4

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

MCCLELLAN, CA, 95652-2100, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Defense Microelectronics Activity
Contacts1 person available
OfficeMCCLELLAN, CA, 956522100, USA
Office AddressMCCLELLAN, CA, 956522100, USA
Contacts
Robynn L. HaganContract Specialist

Full Description

Show more
K = Combined Synopsis/Solicitation Notice Set Aside: None Classification Code: J061 - Maintenance, Repair, and Rebuilding of Equipment- Electric Wire and Power Distribution Equipment NAICS Code: 811310 - Commercial and Industrial Machinery Equipment This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the solicitation to provide facility preventative, remedial & emergency, and over & above services on Eaton UPS system in Bldgs 1 & 2. The NAICS Code is 811310 with a size standard of $7M. DPAS Rating is S10. This requirement is 100% set-aside for small businesses. The services are to be performed at Defense MicroElectronics Activity (DMEA) Bldg 1 & 2, 4234 54th St, McClellan, CA . Solicitation HQ0727-14-R-0010 is issued as a request for proposal. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-71 effective 30 Jan 2014. See http://farsite.hill.af.mil/ for the full text of all provisions and clauses incorporated by reference herein. Offerors are requested to submit a written proposal in response to the attached solicitation, dated 6 Feb 2014, on a firm fixed price (FFP) basis for preventative/remedial/emergency and time and materials (T&M) basis for over and above maintenance services for a base period and 2 option periods. If all options are exercised performance would conclude 28 Feb 2017. The government intends to award a firm fixed-price basis for preventative/remedial/emergency with time and materials basis for over and above for contract containing the following contract line item number(s): 0001 Preventative Maintenance 0002 Remedial/Emergency Maintenance 0003 Over and Above 0004 Option Year 1 - Preventative Maintenance 0005 Option Year 1 - Remedial/Emergency Maintenance 0006 Option Year 1 - Over and Above 0007 Option Year 2 - Preventative Maintenance 0008 Option Year 2 - Remedial/Emergency Maintenance 0009 Option Year 2 - Over and Above -Written proposal are due at or before 10:00 AM PST, Thursday, Feb 21, 2014. Email, proposals to: contact@example.gov, or by facsimile to: +1 (555) 000-0000. Offerors are required to submit their proposals using the SF- 1449, Solicitation/Contract/Order for Commercial Items. Proposals shall be valid for 60 calendar days from the date specified for receipt of offers. Proposals will be evaluated based on "best value" in response to the Proposal Requirements in 52.212-2 52.252-1 Solicitation Provisions Incorporated by Reference (Feb 1998) This solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The offeror is cautioned that the listed provisions may include blocks that must be completed by the offeror and submitted with its quotation or offer. In lieu of submitting the full text of those provisions, the offeror may identify the provision by paragraph identifier and provide the appropriate information with its quotation or offer. Also, the full text of a solicitation provision may be accessed electronically at this/these address(es): http://farsite.hill.af.mil/ 52.212-2 Evaluation -- Commercial Items (Jan 1999) (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Proposal Requirements: Contractor proposals shall specifically address the following areas: Technical Approach: Company Support to Large Eaton, 3-phase UPS: The contractor shall list their experience in these areas to include: 01. Locations Supported 02. Work preformed and duration of the work 03. Customer point of contact and telephone number 04. Model number(s) of UPS supported Emergency response time frames for technicians in cause of UPS problem Approach for meeting National Fire Protection Association 70E for work inside electrical panels. Service Technician Qualifications: Provide a list of technicians along with each proposed staff member's specific qualifications/training related of paragraph 5b qualification requirements. Past Performance: The Government will collect and evaluate the information provided by references or through other means to assign a risk assessment. The Government may contact references other than those identified by the offeror and use that information in the past performance evaluation. If the offeror does not have any past performance information, the offeror will be given a neutral rating and will not be evaluated favorably or unfavorably for this criterion. The Contractor shall document its past performance on previous similar contracts. The contractor shall provide references to at least 3 other customers (including company name, point of contact, address, phone number, and email) for whom similar work has been accomplished. References to current and active contracts are acceptable. Price: Provide detailed price list on each item in Technical Exhibit 1. Proposals will be evaluated for realism, completeness, reasonableness, and a total evaluated price to the Government will be calculated. Technical and past performance, when combined, are significantly more important than price. 2. Proposal Requirements: Contractor proposals shall specifically address the following areas: a. Technical Approach: i. Company Support to Large Eaton, 3-phase UPS: The contractor shall list their experience in these areas to include: 01. Locations Supported 02. Work preformed and duration of the work 03. Customer point of contact and telephone number 04. Model number of UPS supported ii. Emergency response time frames for technicians in cause of UPS problem iii. Approach for meeting National Fire Protection Association 70E for work inside electrical panels. iv. Service Technician Qualifications: Provide a list of technicians along with each proposed staff member's specific qualifications/training related of paragraph 5b qualification requirements. b. Cost. Detail cost listed on each item in Technical Exhibit 1 3. The winning proposal will be selected based on "best value" in response to the above technical requirements and price, with equal value given to technical approach and to cost. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). (c) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Provision) 52.252-2 Clauses Incorporated by Reference (Feb 1998) This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es): _http://farsite.hill.af.mil/ SOLICITATION PROVISIONS/CONTRACT CLAUSES: The following FAR & DFAR provisions and clauses apply to and are incorporated in the solicitation either by reference or in full text: 52.202-1 Definitions 52.203-3 Gratuities 52.203-6 Restrictions On Subcontractor Sales To The Government 52.204-9 Personal Identity Verification of Contractor Personnel 52.204-10 Reporting Executive Compensation and First-Tier Subcontract Awards 52.209-6 Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, or Proposed for Debarment 52.212-1 Instructions to Offerors - Commercial Items 52.212-3 Offeror Representations and Certifications - Commercial Items 52.212-4 Contract Terms and Conditions-Commercial Items 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items 52.216-31 Time-and-Materials/Labor-Hour Proposal Requirements-Commercial Item Acquisition 52.217-8 Option to Extend Services 52.217-9 Option to Extend the Term of the Contract 52.219-1 Small Business Program Representations 52.219-4 Notice of Price Evaluation Preference for HUBZone Small Business Concerns 52.219-6 Notice Of Total Small Business Set-Aside 52.219-8 Utilization of Small Business Concerns 52.219-28 Post-Award Small Business Program Representation 52.222-3 Convict Labor 52.222-19 Child Labor - Cooperation with Authorities and Remedies 52.222-21 Prohibition Of Segregated Facilities 52.222-26 Equal Opportunity 52.222-35 Equal Opportunity for Veterans 52.222-36 Affirmative Action For Workers With Disabilities 52.222-37 Employment Reports on Veterans 52.222-41 Service Contract Act Of 1965 52.222-43 Fair Labor Standards Act And Service Contract Act - Price Adjustment (Multiple Year And Option) 52.222-50 Combating Trafficking in Persons 52.222-54 Employment Eligibility Verification 52.223-3 Hazardous Material Identification and Material Safety Data 52.223-5 Pollution Prevention and Right-to-Know Information 52.223-18 Encouraging Contractor Policies To Ban Text Messaging While Driving 52.232-18 Availability Of Funds 52.233-2 Service of Protest 52.233-3 Protest After Award 52.233-4 Applicable Law for Breach of Contract Claim 52.237-1 Site Visit 52.237-2 Protection Of Government Buildings, Equipment, And Vegetation 52.237-3 Continuity Of Services 52.242-13 Bankruptcy 52.243-1 Alt I Changes-Fixed Price (Aug 1987) - Alternate I 52.245-9 Use And Charges 52.252-1 Solicitation Provisions Incorporated by Reference 52.252-2 Clauses Incorporated by Reference 52.253-1 Computer Generated Forms 252.201-7000 Contracting Officer's Representative 252.203-7000 Requirements Relating to Compensation of Former DoD Officials 252.203-7002 Requirement to Inform Employees of Whistleblower Rights 252.203-7005 Representation Relating to Compensation of Former DoD Officials +1 (555) 000-0000 Line Item Specific: Single Funding 252.204-7000 Disclosure Of Information 252.204-7003 Control Of Government Personnel Work Product 252.204-7012 Safeguarding of Unclassified Controlled Technical Information 252.209-7001 Disclosure of Ownership or Control by the Government of a Terrorist Country 252.212-7001 (Dev) Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (Deviation) 252.215-7008 Only One Offer 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports 252.232-7006 Wide Area WorkFlow Payment Instructions 252.232-7009 Mandatory Payment by Governmentwide Commercial Purchase Card 252.232-7010 Levies on Contract Payments 252.237-7019 Training for Contractor Personnel Interacting with Detainees 252.243-7002 Requests for Equitable Adjustment 252.244-7000 Subcontracts for Commercial Items G-909 WAWF Submittal Information (Local) H-931 Required Insurance H-957 Contractor Manpower Reporting J-000 List of Attachments STATEMENT OF WORK (SOW) Rev 1 DMEA 14-4A8 28 January 2014 Preventative and Remedial/Emergency Maintenance, and Over-And Above Work Supporting Defense Microelectronics Activity (DMEA) Eaton Powerware 9315-500 Model 500 Uninterruptable Power Supply (UPS) Serial Number: ET4227XX09 And Four Each Battery Cabinets (160 Batteries Total) And Eaton Power Xpert 9395-275-275-CA UPS Serial number EG096BAA03 with 2 battery cabinets (80 batteries total) 4. Objectives: a. The contractor shall maintain the proper operation of the DMEA UPS by accomplishing preventative maintenance (PM) and remedial maintenance in accordance with the equipment manufacturers' specifications. The contractor shall strive to keep DMEA UPS system operational at all times. The service technicians shall be fully versed on all repairs to the Eaton equipment and shall be held responsible for not causing critical load drops caused by their maintenance activities (unless a utility outage during work in the bypass mode), or for equipment failures after the annual PM that should have been noticed during the service. Dropping of the critical loads shall be reviewed by the Contracting Officer, DMEA Operations Manager and Contractor Service Manager and can be grounds for DMEA unilateral termination of the contract. b. The contractor shall provide same day 24/7 emergency maintenance when directed by the DMEA Contracting Officer Representative (COR) with the contractor's service technicians arrival at DMEA within 4 hours of DMEA notification. 5. General Requirements a. Scope of Work: The Defense Microelectronics Activity (DMEA) complex at 4234 54th Street, McClellan, CA consists of three facilities: Building 1 a 75,000 sq foot facility, Building 2 a 30,000 sq ft facility and the Central Utility Plant (CUP).. The Contractor shall provide all equipment, tools, materials, supervision, and all other items and services necessary to perform preventive and remedial (emergency & non-emergency) maintenance on UPS. The contractor shall perform work on the UPS as defined in this SOW, and over-and-above work related to the UPS as directed by the Contracting Officer's Representative (COR) or Contracting Officer. A service report shall be submitted to the COR within 3 business days following any maintenance work performed on this equipment and shall correspond to the information at Technical Exhibit 1. b. Enterprise-wide Contractor Manpower Reporting Application (eCMRA): The contractor shall report ALL contractor labor hours (including subcontractor labor hours) required for performance of services provided under this contract for the Defense Microelectronics Activity via a secure data collection site. The contractor is required to completely fill in all required data fields using the following web address: http://www.ecmra.mil/. Reporting inputs will be for the labor executed during the period of performance during each Government fiscal year (FY), which runs October 1 through September 30. While inputs may be reported any time during the FY, all data shall be reported no later than October 31 of each calendar year beginning 2014. Contractors may direct questions to the help desk at: http://www.ecmra.mil/. 6. Specific Requirements. a. Preventative Maintenance (PM): The contractor shall replace consumable items (e.g. air filters) and perform PM actions (such as checking connections, etc.) based on the attached Technical Exhibit 1. Contractor shall replace all batteries in one battery cabinet (40 batteries) and recycle the old batteries. Use Eaton 1085/J47 maintenance free batteries. Coordinate with DMEA on which battery cabinet to replace batteries. b. Remedial/Emergency Maintenance: The contractor shall perform remedial maintenance activities based upon issuance of a work order or credit card authorization from the COTR or Contracting Officer. Remedial maintenance includes replacement of batteries and similar non frequent repair actions. Contractor shall submit a written quote identifying any requested or recommended repairs to the COR for approval prior to performing any work. Emergency repairs may be quoted verbally for immediate approval but shall be followed up with a written quote the next work day. c. Over-and-Above Work: The contractor shall perform over-and-above activities based upon issuance of a work order from the Contracting Officer or credit card authorization. Over-and-above work could include modifications or additions beyond normal maintenance activities. These requirements can be generated by the DMEA Facility Engineer or by the contractor to improve system operation and reliability. For contractor suggested modifications, the contractor shall provide a written quote that shall include an explanation of why the enhancement is recommended. i. 3. Optional Items: The contractor shall include in their proposal the cost to provide and install the following Eaton UPS upgrades in the base year and each option year: 01. Eaton Energy Saver System (ESS)/VMMS Upgrade (Eaton Part Number P-10300476) 02. Develop design to improve the reliability of the DMEA back-up power system and add backup power capability for the entire plant within Building 620. This would be accomplished by marking-up the existing plant single line diagram with new or altered circuits, N+1 redundant generators, N+1 redundant UPS's, as well as recommendations for replacement or upgrades to circuit breakers in the main switchboard and downstream panelboards. Provide proposed equipment lists, cost estimates and recommended phasing for accomplishing the enhancements over a 3-5 year period. For the purpose of bidding, this task shall not exceed 120 hours of engineering time. d. Government Purchase Card (GPC): The Government Purchase Card will be used as the method of payment for fixed price remedial maintenance and over-and-above repair work under $2,500. Such repairs will be authorized in advance by the GPC holder. No work orders will be issued. The contractor must accept the GPC credit card for payment for requirements under $2,500. 7. Quote and Work Orders. a. The contractor shall establish a quote, work order/credit card authorization, scheduling, and tracking process for remedial maintenance and over-and-above work ordered by DMEA. i. Contractor Quotes: Quotes shall include the itemized equipment purchase costs, labor and material costs derived from established standards or historical data. The detailed estimate shall be submitted to the Government for review and Contracting Officer approval prior to the start of any remedial or over-and-above work. Contractor format is acceptable for quotes. b. Work Order Authorization: The government will issue written work orders (DMEA Form 500) for requirements over $2,500. The Contracting Officer may authorize remedial and over-and above tasks by issuance of a work order. c. Emergency Quotes and Work Order Authorization. In case of emergencies, the contractor's response service technician shall have the authority to provide a verbal, not-to-exceed time and material quote for emergency repairs 24-hours-a-day, 365 days per year. Work order documents, numbers and government approvals may be verbal so as to allow immediate repair and the written quote shall be provided the following workday, and a work order will be issued by DMEA if required. d. Emergency Contact. The contractor shall provide DMEA 24 hour, 365 days per year contact numbers for service technicians 8. Contractor Personnel: a. Service Manager and Service Technicians: The contractor shall assign a Service Manager, and several service technicians to assure that performance of work accomplished under this contract is conducted in accordance with this SOW. The names of these persons shall be designated in writing and this designation provided to the DMEA Contracting Officer at the beginning of the contract and whenever changes are required. The Service Manager shall have authority to act for the contractor on all contractual matters relating to daily operations of this contract. In case of Service Manager absence, or off-shift emergency, the assigned technicians may serve on their behalf regarding work under this SOW. The Service Manager and all technicians must be able to fluently read, write, speak, and understand English. b. Power System Engineering Support: The contractor shall have at least one California Registered Professional Engineer (PE) to provide any engineering support needed due to equipment failures, as well as to design back-up power system modifications and equipment additions under this contract The engineer shall provide proposed designs, equipment lists, project phasing recommendations, approval drawings and stamped final drawings as needed. c. Technician Qualifications: The service technicians shall be thoroughly familiar with the operation, maintenance and repair of equipment hardware and controls used on UPS. The service technicians shall have at least 5 years prior experience working on large Eaton UPS systems. The contractor shall immediately notify DMEA COR of any staffing changes impacting work under this Statement of Work. d. Employee Attire, Identification and Safety Equipment: Contractor personnel shall wear appropriate attire and safety equipment for the work to be performed. Contractor personnel shall be neat in appearance and fully clothed (shirts, blouses, trousers, overalls or coveralls must be worn - fire resistant clothing is recommended, safety glasses, etc) during the execution of their duties under this SOW. Contractor's personnel shall be easily recognized via uniforms that include the name of the Company and the name of the employee. The cost of the uniforms and safety equipment is the responsibility of the Contractor. e. Contractor Vehicle Operation: The contractor shall ensure employees have a current and valid California driver's license before allowing the employee to operate a contractor-owned vehicle at the Defense Microelectronics Activity, McClellan, CA. All vehicles entering DMEA property shall be clearly marked with the company name and shall be company owned. 9. Vehicle Insurance: The contractor shall provide a minimum of $100,000 liability (property and bodily injury) vehicle insurance and provide proof of insurance to the DMEA Contracting Officer prior to starting work. 10. Conflict of Interest: The contractor shall not employ any person who is an employee of the US Government if employing that person would create a conflict of interest. Additionally, the contractor shall not employ any person who is an employee of the Defense Microelectronics Activity, either military or civilian, unless such person seeks and receives approval of DMEA Staff Counsel. 11. Response Time: Remedial (emergency & non-emergency) maintenance services response time shall be determined based on whether the problem prevents proper operation of the UPS. For example replacement of working batteries, which are four years old, would be a non-emergency and the contractor could provide a quote to DMEA within three work days of notification by DMEA or discovery by the contractor's service technicians (during PM). Work shall be completed within the time frame listed and accepted in the contractor's quote. For emergency repairs (e.g. the UPS has failed, or can only operate in by-pass mode), the contractors service technicians must arrive at DMEA within 3 hours and be ready to conduct the repair immediately upon DMEA authorization. 12. Quality Control (QC), Invoices and Service Reports: Quality Control is the Contractor's responsibility. The Contractor shall establish and maintain an efficient and effective QC Program to ensure conformance to contract requirements. The QC approach shall be linked directly to requirements in Technical Exhibit 1 so that service reports, and QC verification (work was done and done correctly) can all be tied to the technical exhibit. The contractor, via the QC Program, shall verify that all work required in Technical Exhibit 1 is completed properly. Within 15 days after contract award the contractor shall provide the DMEA Contracting Officer their QC plan. The Contractor shall, within 3 working days of each preventative maintenance visit, provide a service report to the COR. The report shall include notification of any deficiencies identified and any further repairs recommended. If further repairs are recommended, the contractor shall provide a written quote for the additional remedial maintenance or over-and-above work to the COTR. 13. Code Compliance: The contractor shall abide by the State of California's latest building code for all work, including National Electrical Code and National Fire Protection Association (NFPA) standards. DMEA will inform the contractor of any work accomplished under this SOW that is found by DMEA, or DMEA third party certified professional inspectors, not to meet code within 12 months following completion. DMEA hires a professional engineering firm to conduct code compliance visits as part of an annual safety inspection. Code compliance issues shall be reviewed by the contractor's service manager and corrected promptly at no additional cost to DMEA. Code compliance shall be checked against codes in place at the time of installation. COR acceptance of the work does not relieve the contractor of the contractor's responsibility for code compliance. 14. Maintenance Schedule. The schedule shall be in accordance with Technical Exhibit 1. The contracting officer shall approve any changes to the maintenance schedule. All PM work must be scheduled in advance (minimum two working days) with DMEA to ensure there are no conflicts (e.g. time sensitive production/testing runs, VIP visits, etc.). PM and non-emergency repair work must be scheduled for the foundry maintenance Friday (every other Friday 0630 -1500) so as not to impact ARMS operation. During repair activities, the UPS can be placed in "maintenance by-pass" but power must not be interrupted to down stream equipment because of the maintenance. Additionally, if winds are forecast to be above 15 mph in Sacramento California the day of the PM service or other approved contract actions, the UPS shall not be placed in maintenance by-pass and the service shall be rescheduled at no cost to DMEA. 15. Quality Assurance (QA): Quality Assurance is a Government responsibility. The Government will monitor the Contractor's performance under this SOW using a combination of 100% Inspection and Random Inspection Procedures as defined in the Quality Assurance Surveillance Plan (QASP) prepared by DMEA. A copy of the QASP will be provided to the contractor at contract award, as well as an appointment letter for the COR. This letter will define the COR's responsibilities and limits of authority . 16. Hours Of Operation*: DMEA's normal business hours are Monday - Friday, 0600-1600 hours except Federal holidays, including: a. New Year's Day - 1 January b. Martin Luther King Day - 3rd Monday in January c. Washington's Birthday - 3rd Monday in February d. Memorial Day - last Monday in May e. Independence Day - 4 July f. Labor Day - 1st Monday in September g. Columbus Day - 2nd Monday in October h. Veteran's Day - 11 November i. Thanksgiving Day - 4th Thursday in November j. Christmas Day - 25 December *Note: If these holidays fall on Saturday, the preceding Friday will be observed, if these holidays fall on Sunday, the following Monday will be observed. If a holiday falls on a regular workday, the services shall be rescheduled in the same week to either the day preceding or following the holiday. 17. Government-Furnished Property and Services: The Government will not furnish any tools, equipment or items to the Contractor under the terms of this SOW. 18. Contractor Furnished Equipment. The Contractor shall provide all equipment, tools, safety equipment, materials and services to perform work under this SOW. 19. Work Restrictions: The contractor and their staff shall abide to the following: a. As a DoD facility, all contractor personnel on-site must be US citizens. b. The DMEA facility is access controlled and all personnel are required to have a background check in advance of working at the site. The contractor shall submit background check release forms and badge requests forms for all personnel expected to work on this project at least 4-weeks prior to project start. The on-site contractor personnel will be issued a badge each day while on site and shall return their badge to DMEA security personnel at the end of the day or when leaving the site. Any contractor personnel showing up at DMEA without a pre-arranged badge request and background check shall not be allowed to access the DMEA facility. For security and facility access purposes, the contractor shall assign specific technicians to the DMEA work. c. All work under this SOW shall be coordinated with a member of the DMEA Facility Team (Facility Engineer, CO/Facility Manager) to keep the DMEA Facility Team aware of contractor activities. d. Work Permits: DMEA has an extensive gas alarm system and fire alarm system that is susceptible to activation from contractor activities (solvent use, grinding, welding, soldering, refrigerant work, etc.). DMEA lab, clean room and security systems are sensitive. Therefore, to avoid potential alarms and subsequent facility evacuations caused by contractor activities, the contractor's technician shall submit a work permit to DMEA Facility Manager with assistance from the DMEA facility/environmental team for any work that involves the items listed below. The forms will be reviewed, evaluated and approved by the DMEA facility and environmental/safety team before work is initiated. Repeated failure to obtain a work permit when required, or fire/gas alarms caused by improper work may, at the discretion of DMEA, be reason for default or consideration action under the terms of the contract. i. Hot Work: Such as soldering, brazing, welding, or grinding. ii. Solvents/chemicals/gases such as alcohols, paint thinners, aerosol cans, refrigerants (R-123 and others), odorous materials, paints and epoxies, adhesives including contact cement, PVC and ABS glue, etc. iii. Electrical Work (energized and shut down) such as wiring, panel work, and new equipment connections - including work on the UPS. e. Space in the back lot of Building 620 is very tight; therefore, the contractor shall be limited to one vehicle in the back lot at any time subject to space availability. Parking in the west area (54th Street) is preferred. f. Safety: The Contractor shall provide and use safety cones/signs alerting DMEA personnel when work is being preformed in walkways. The contractor shall not leave any electrical boxes or panels open and unattended and shall use safety cones and signs when electrical hazards are present. g. Damage to Finishes and Property: Building finishes or government or private property soiled or damaged due to the Contractor's operations shall be cleaned, repaired, replaced, or restored to condition not less than that existing immediately prior to the damage and without cost to the Government. Repeated damage to Government or private property shall, at the discretion of DMEA, be reason for default action under the terms of the contract. h. Cleanup: All Contractor supplies, equipment, and tools shall be kept out of traffic lanes or other areas where they might be a safety hazard unless it is absolutely essential for the performance of the repairs being made, and then properly coned off to reduce the hazard. Disposition of all parts, trash, and debris shall be accomplished at the completion of work, and area shall be thoroughly cleaned before Contractor leaves the area. Contractor shall remove and properly dispose of any contractor generated hazardous materials along with their containers that were used on site while performing their work. The contractor shall identify any hazardous materials necessary to perform preventative or remedial maintenance and provide a copy of the applicable material safety data sheet to the COR and Contracting officer 20. Proposal Requirements: Contractor proposals shall specifically address the following areas: a. Technical Approach: i. Company Support to Large Eaton, 3-phase UPS: The contractor shall list their experience in these areas to include: 01. Lo...

More opportunities from Department Of Defense → Defense Microelectronics Activity

Same awarding agency

NAICS: 513210
New
Federal
Altium Server and Licenses
Solicitation # HQ072727QMH03
The Defense Microelectronics Activity is soliciting a firm-fixed-price contract under solicitation HQ072727QMH03 to upgrade its existing Altium license suite to Altium Enterprise and install an on-premises Enterprise server. This initiative aims to provide critical military design capabilities, including version control, configuration management, and component life-cycle management. The scope of work requires the installation and functional validation of the server by March 31, 2027, ensuring successful connection to a high availability SQL database cluster endpoint and a designated HA file share network path. Additionally, the contractor must demonstrate software interoperability, specifically with Solidworks Professional, and potentially with Keysight ADS, CST Antenna Magus, and PCB Doctor. The contract structure consists of a base period for the server installation and an initial four-month upgrade of 16 licenses, followed by three optional one-year renewal periods for 20 Altium Enterprise licenses extending through April 12, 2030. Award will be based on the best value, with price as the sole evaluation factor. Quotes are due by November 4, 2026, to Contracting Officer Mike Hallock. The procurement is justified as a sole source due to the proprietary nature of the software and the need to avoid incompatibility risks with existing PCB design tools.
Software Publishers

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS