Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

BELPAS-2569 Replace 2" underground water line.

Forecast
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of the Navy, through Navfac Europe Africa Central, is seeking a contractor to replace a deteriorated two inch underground water line feeding building 2569 in Sigonella. The existing galvanized piping, installed in 2005, is suffering from calcium build-up and severe deterioration, posing an immediate risk of failure in the boiler room. The project is categorized as a Category 3 EV requirement and necessitates close coordination between FMD and FSC regarding quarter execution. The scope of work includes excavating asphalt parking and grass areas to expose and disconnect the old pipe from an existing gate valve. The contractor must install a new water line at a depth of approximately 1 to 1.2 meters, drill through the boiler room exterior wall, and connect the line to the existing backflow preventer. All necessary hardware, fittings, and joints must be provided. To ensure safety and compliance, the contractor is required to perform a full disinfection of the water line using a chlorine solution to meet potable water standards while coordinating connections to minimize water outages.

General Info

Contractor to replace deteriorated underground water line for building 2569 in Sigonella.

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

E: SIGONELLA, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseForecast
Posted

forecast

Prepare for this forecast

Research the agency, track this forecast, and prepare your capture plan before the solicitation opens.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Europe Africa Central
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
7 AUG 25 WIB Decision: FMD / FSC Coordination on quarter execution needed. Cat 3 - EV --------------- 1. CURRENT CONDITION: • Water line feeding building 2569 is extremely deteriorated. The portion of pipe exposed in the boiler room may break anytime. • The pipe seems to be galvanized type installed in 2005 and it is partially clogged by calcium build-up. • In accordance with existing drawings, the excavation will required the crossing of the parking and grass area to reach the water main located along the main road. See attached plan. 2. REQUIREMENT: Provide labor, materials and equipment to: • Excavate the asphalt parking area to of the expose the water pipe including partial demolition. • Disconnect the old pipe from the existing gate valve (this valve is part of Pizzarotti property). • Run the new pipe and connect to the existing valve. Abandon the old pipe on site. • Drill the exterior wall of the boiler room and run the new pipe thru the wall. Due to the presence of the outdoor gas ramp and indoor piping, the exact position shall be determined on site. • Connect the new pipe to the existing backflow preventer (BFP). This work will require partial reconfiguration of the existing piping layout. • The connection work of the new water line at both ends shall be coordinated so to minimize the time of the water outage. • The contractor shall provide fittings, joints flanges, fittings, bolts, connectors and all the hardware required for the installation of the new water line. • Depth of the pipes is about 1.÷1.2mt below ground level. • Perform disinfection of the water line to meet potable water repair requirements (i.e. disinfected in advance with a chlorine solution at a minimum concentration of 1%, etc.). The Contractor shall disinfect the water line i ... NOTE: description has been truncated, please see Project Note for full description.

Similar Contracts

Same NAICS industry code

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project for the City of Belmont, North Carolina, involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and significant upgrades to the Morgans Branch Pumping Station. The scope of work includes installing a new wet well and valve vault with associated appurtenances, as well as the demolition of existing pumps and piping. The project has an estimated value of 16,690,000 dollars and a performance period of 560 calendar days following the issuance of a Notice to Proceed. The contract is administered using EJCDC standard forms and will be awarded to the responsible bidder submitting the lowest responsive bid. Key requirements for bidders include the submission of bid security, evidence of authority to sign, and specific M/WBE compliance documentation, including a Good Faith Efforts Form and Table A. Participation goals are set at 10.9 percent for MBE and 10.4 percent for WBE per EPA guidelines, with a combined state goal of 10 percent. The contractor must provide performance and payment bonds, maintain insurance from providers with an A.M. Best rating of A-VII or better, and adhere to OSHA fall protection and various technical standards, including AWS D1.2 for welding and NEMA MG1 for motors. Payment will be processed in equal monthly amounts via EJCDC C-620 applications, with a 200,000 dollar contingency allowance available for authorized additional work.
Don Moorhead Construction, Inc.

POSTED

about 1 hour ago

DEADLINE

in about 16 hours
View Details
NAICS: 237110
New
Jefferson St. Pump Station Replacement
Solicitation # ITB-2026141
The City of Winchester is soliciting bids for the Jefferson Street Pump Station Replacement project in Virginia under solicitation ITB-2026141. The scope of work includes the construction of a new pump station featuring a precast concrete building, controls, and a standby generator, as well as site electrical work, yard piping, security fencing, grading, and paving. Additionally, the project requires the relocation of an existing fuel tank and the demolition of existing facilities. All work must be completed within 610 calendar days following the Notice to Proceed, with adherence to VDOT 2020 Road and Bridge Specifications and the City of Winchester Standards Manual. WG Construction is seeking MBE/WBE subcontractor participation for paving, material supply, site development, fencing, MEP, roofing, and carpentry. Bids are due by 2:00 pm on November 12, 2026, via the City's e-Procurement Portal. The contract will be awarded to the lowest responsive and responsible bidder based on qualifications, compliance, and pricing. Requirements include a 5 percent bid guarantee, performance and payment bonds equal to 100 percent of the contract amount, and compliance with Davis-Bacon wage determinations and OSHA safety standards. Bidders must provide a minimum of three similar project references and confirm they are not on any government debarment lists.
WG Construction Co., Inc.

POSTED

about 1 hour ago

DEADLINE

in about 16 hours
View Details

More opportunities from Department Of The Navy → Navfac Europe Africa Central

Same awarding agency

Prepare for this forecast

Research this forecast and prepare for the solicitation

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS