The 55th Contracting Squadron at Offutt Air Force Base, Nebraska, is conducting a sources sought announcement to identify qualified contractors capable of performing emergency power and switchgear automation controls repair services at USSTRATCOM’s Building 1000. The effort involves upgrading, repairing, or replacing components of emergency power generator systems and electrical switchgear systems to ensure resilient, uninterrupted power delivery. Contractors must provide all personnel, equipment, supplies, tools, and non-personnel services required to complete the work within a six-month period. The work requires OEM (ABB) certification for all personnel working on the systems, adherence to a Quality Control Plan and Quality Assurance Surveillance Plan, and compliance with cybersecurity requirements including CMMC Level 1 certification as mandated by DFARS 252.204-7021. Contractors must be registered in SAM.gov, provide their CAGE Code and Unique Entity Identifier, and disclose their small business status and eligibility in any socioeconomic categories, with small businesses required to perform at least 51% of the work internally. Deliverables include comprehensive documentation such as System Operations and Failure Analysis, system restoration methods, commissioning test logs, video training materials, and progress meeting slides. The contractor must designate a certified PLC Programmer and Project Manager, who must be available during normal business hours, and is responsible for obtaining government approval for any hardware or software replacements exceeding $300. All work occurs at the facility located at Offutt AFB, and contractor employees must hold a Department of Defense Common Access Card, with strict prohibitions against video recording in sensitive areas and immediate replacement of lost or duplicated keys at contractor expense. Responses must include a three-page capability summary with company information, cybersecurity and OEM certification confirmation, NAICS code feedback, and PWS comments, submitted via email to the designated contracting officers no later than May 4, 2026. The Government is currently considering NAICS code 811310 but invites feedback on potential alternatives. No contract has been issued, and this posting is strictly for market research purposes with no solicitation or obligation to award.
General Info
Agency
NAICS
Place of Performance
St Columbans, NE, 68113, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Sources Sought Announcement
Emergency Power and Switchgear Automation Controls Repair
at Offutt AFB, NE
The 55th Contracting Squadron is seeking sources for the Emergency Power and Switchgear Automation Controls Repair effort.
CONTRACTING OFFICE ADDRESS: 55 CONS/PKT
106 Peacekeeper Lane, STE 2N3
Offutt AFB, NE 68113
- INTRODUCTION
- This is a Sources Sought notice being conducted pursuant to RFO Part 10, Market Research. This is for planning purposes only and there is no solicitation available at this time.
- The 55th Contracting Squadron at Offutt Air Force Base, Nebraska, seeks potential contractors to submit their interest and ability to provide all personnel, equipment, supplies, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Emergency Power and Switchgear Automation Controls Repair.
- The interested contractors shall identify their ability to provide upgrades, repairs, and/or replacements to the Emergency Power Generator Systems and Electrical Switchgear Systems located within B1000 United States Strategic Command (USSTRATCOM) IAW the PWS.
- Period of Performance: It is anticipated by the Government that this effort shall take no more than six (6) months to complete. The Government requests feedback and justification regarding the viability of this schedule.
- For this effort, the Government is considering the North American Industrial Classification Systems (NAICS) code of 811310 (Commercial and Industrial Machinery and Equipment Repair and Maintenance). The Government requests feedback and justification if a different NAICS code would be more suitable for this effort.
- INFORMATION AND INSTRUCTIONS
- All contractors capable of and interested in providing these services are invited to respond. Any information provided to the Government as a result of this Sources Sought is voluntary and the Government will not pay for any information submitted. Respondents are required to submit capability packages, as described below.
-
-
- Capabilities packages should include up to a 3-page capability summary. Text should be no smaller than 11-point font and include:
- Company Information: Provide company name, address, a point of contact with e-mail address and telephone number, Cage Code, Unique Entity Identifier, business size, and security clearance level (if available). Your company must be registered in System for Award Management (SAM). To register, go to https://www.sam.gov.
- Small Business: Small business respondents to this announcement should indicate whether they are a small business, 8(a) concern, veteran-owned small business, service-disabled veteran-owned small business, HUB Zone small business, small disadvantaged business, women-owned small business, etc. Additionally, if your company is a small business, you must be capable of performing at least 51% of the total requirement within your own company.
- Cybersecurity Maturity Model Certification (CMMC) certification level: Please note a Level 1 Cybersecurity Maturity Model Certification (CMMC) is required at the time of award. See DFARS 252.204-7021 for contractor compliance.
- Confirmation of Certification: The contractor must confirm that all contractor employees working on the USSTRATCOM systems would be certified by the OEM (ABB) for the system being worked on.
- NAICS Request: As stated in paragraph A.5. above, the contractor provide feedback and justification if a different NAICS code would be more suitable for this effort.
- PWS Feedback: The Government requests contractor feedback on attached PWS.
- Capabilities packages should include up to a 3-page capability summary. Text should be no smaller than 11-point font and include:
-
Capabilities statements shall be emailed to Amanda Smith amanda.smith.70@us.af.mil and Elizabeth Dennis elizabeth.dennis.2@us.af.mil NLT 1100 (CST) Monday, 4 May 2026.
More opportunities from Department Of Defense → FA4600 55 Cons Pkp
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS