OUTLYING - CAMSMI 700 - AE DESIGN - REPLACE 3 TRANE 266 TON CHILLERS & PLANT PUMPS

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This project involves the design and replacement of three 266-ton Trane centrifugal chillers and associated plant pumps at the USPACOM Utility Building 701 for Navfac Hawaii. The existing units, in operation since 2003, have reached the end of their service life and suffer from refrigerant leaks and inefficiency. The scope of work includes the demolition and removal of the old chillers and the installation of new high-efficiency water-cooled centrifugal or screw chillers equipped with VFD controls. The project also requires the replacement of miscellaneous piping, fittings, valves, and insulation, as well as upgrades to the refrigerant leak detection system. To maintain continuous central plant operations, the chillers must be replaced one at a time. The new equipment will be integrated into the existing Trane Tracer BAS system, utilizing existing direct-digital controls. Following installation, the contractor must provide comprehensive testing, adjusting, and balancing of the water system. This energy-focused initiative aims to modernize the facility's cooling capacity and operational efficiency while ensuring no disruption to the chilled water service provided to Building 700.

General Info

Replace three 266-ton chillers and pumps at USPACOM Building 701 for Navfac Hawaii.

NAICS

541330 - Engineering Services

Place of Performance

USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Hawaii
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
**Maximo WO# HQ GSXC6F (DESIGN)***USPACOM Replace 3 Trane 266 ton centrifugal chillers. The existing HVAC system in B701 has 3 266 ton Trane chillers that provide chilled water to B700. The 3 chillers have been in operation since 2003. All 3 chillers are leaking refrigerant, are inefficient and have reached the end of their service life. The chillers need to be replaced with new high efficiency chillers. Scope of work: Replace 3 266 ton chillers in B701 with new chillers installed in the existing chillers location. Demolition of the existing chillers and its complete removal from the site. Disconnection and reconnection of the existing chilled water piping to serve the new chiller, miscellaneous piping, fittings, valves, couplings, and pipe insulation as required for a complete and operational system. The new chillers will be connected to Trane Tracer BAS system. Provide testing, adjusting and balancing of water system after installation of new chillers. Upgrade Refrigerant Leak detection system as required. The central plant is required to operate continuously. Installation of the chillers will need to be done one at a time to ensure plant will stay operational throughout install. Energy scope: This energy project will replace three (3) deteriorated 266-ton water-cooled centrifugal chillers located in the PACOM Utility Building 701 with higher capacity and higher efficiency water-cooled centrifugal or screw chillers with VFD controls. Miscellaneous piping, fittings, valves, couplings, and pipe insulation will be also replaced as required for a complete and operational system. The new chillers will be connected to the Trane Tracer BAS system and the existing direct-digital controls (DDC) will be reused. In addition, the existing three (3) 15 horsepower (HP) primary chilled water pumps, (3) 40 HP secondary chil ... NOTE: description has been truncated, please see Project Note for full description.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of The Navy → Navfac Hawaii

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS