Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

UM - RM23-1481 - SLUDGE THICKENING IMPROVEMENTS AT JBPHH WWTP

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac HawaiiView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Hawaii
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Hawaii
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
This project combines UM - WW - REPLACE WWTP SUBNATANT PIPING and UM - INSTALL DRUM THICKENERS AT JBPHH WWTP projects. Scope for Subnatant Piping: Scope involves constructing a replacement 8-inch subnatant force main from the Disolved Air Flotation Tanks System Subnatant Wetwell Pump Station to the Influent Channel of the Anoxic/Aeration Tanks. Work will include trenching and installing approximately 140 feet of new HDPE force main, connecting the force main to the existing subnatant pumps, and coring a hole through the wall of the influent channel and affixing the new pipe end in place. The existing force main is severely corroded and has recently (within the last nine months) broken several times; each time, a spill is recorded and reported to the State Department of Health. Scope for Drum Thickeners: Justification: Induction of this project is required due to the recent Notice of Violation Order (NOVO) for the WWTP. Several deficiencies were identified that need to corrective action which involves repairs. Project scope involves: purchasing and installing two new drum thickeners outside of the existing dissolved air floatation tanks (DAFTs) building; connecting primary sludge and waste activated sludge lines to inlet of floculation tanks for drum thickeners; connecting polymer tote to polymer feeder; connecting drum thickener outlet to existing sludge transfer pumps; connecting power to new drum thickeners.