This Solicitation opportunity from Department Of Veterans Affairs was posted on September 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Z1DA--554-26-106 Replace DW Valves.
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
Solicitation 36C25926R0057, issued by the Department of Veterans Affairs Network Contracting Office 19, is a total set-aside for verified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238220. The project involves the replacement of approximately 29 domestic water valves across multiple buildings at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The primary objective is to install isolation shutoff valves on domestic cold water, hot water, and hot water recirculation lines to enable individual building isolation from the campus water supply. The estimated project magnitude is between $250,000 and $500,000, with a performance period of 140 calendar days from the notice to proceed. The scope of work is governed by technical specifications in Attachment A and Attachment B, and requires compliance with ICRA Level I standards. Contractors must provide all labor, tools, and materials, ensuring that all equipment is bar-coded and properly labeled according to ASME A13.1. Evaluation factors for the award include price, past performance in a hospital environment within the last five years, and compliance requirements, such as an Experience Modification Rate (EMR) of 1.0 or less and a limited history of OSHA or EPA violations. Key administrative requirements include a digital bid bond of 20 percent of the bid price, adherence to Davis-Bacon Act labor standards, and the submission of a signed Limitation on Subcontracting certification. Recent amendments have clarified the scope by removing a hot water valve requirement for Building B and providing updated RFI responses.
General Info
Place of Performance
COSet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
To provide revised SOW removing the requirement for a domestic hot water valve for Building B and correct ICRA Level requirements per original attachment in the Solicitation Level I and not Level II.
To include attachments Attachment A - 01-PP-100-set r1 and B Attachment B -DWS Valves relative to the RFI s. All other items and conditions remain the same.
More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS