(23522220) Delta Pier Voltage Regulator Replacement, B7035 Bangor
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac NorthwestView Agency
NAICS
N/A
Place of Performance
NW: BANGOR PDC, USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
DBB-IH (Old MSR 22055102 for history) The existing Delta Pier voltage regulator has failed multiple times and is under-sized, resulting in significant risk to mission capabilities. Rebuilding the existing regulator does not solve the sizing problem. Perform complex short-circuit, load-flow, and transient stability engineering analysis and design to determine the quantity, ratings, location, and settings of regulators required to provide regulated voltage to the shore and industrial power loads on Delta Pier. Analysis and design shall include normal and emergency power scenarios and scenarios where the Delta North and South feeders at B7035 are looped (both breakers closed) and radial (one breaker open). Design shall include seismic requirements for the anchorage of the voltage regulators. Design shall include the demolition of existing regulator, protection, equipment pads, and conductors. Design shall regulate voltages within the limits required for submarine shore power as specified in the latest edition of UFC 4-150-02. Perform field investigation and gathering of metering data to perform the analysis. Install temporary demand meters where existing facilities are not metered and where existing meters are not functional. Design shall provide microprocessor-based relays for thermal, overcurrent, and differential protection of the regulators. Protection shall coordinate with existing equipment connected to the line and load side of the regulators. Design shall include modifications to existing equipment. Design shall provide for pad-mounted, metal-enclosed voltage regulators of dead-front construction. Design shall provide dead-front bypass switches for regulator maintenance. Controls shall be located in stainless steel enclosure accessible to personnel without opening the high-voltage termination compartment. D ... NOTE: description has been truncated, please see Project Note for full description.
More opportunities from Department Of The Navy → Navfac Northwest
Same awarding agency