Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

(DB-IH) Conduct Fire Protection Design, Dry-Dock Pump Well, Bldg. 7424, TRF-Bangor (20340242)

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac NorthwestView Agency

NAICS

N/A

Place of Performance

NW: BANGOR PDC, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Northwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
DELIVERABLE: CAT2, DB-IH PSC CODE: C1EC – ARCHITECT AND ENGINEERING-CONSTRUCTION, OTHER INDUSTRIAL FACILITES UNIFORMAT MASTER SYSYTEM: D40 – FIRE PROTECTION REQUESTED SCHEDULE: DESIGN FY24 Q4 – CONSTRUCTION FY25 Q4 LOCATION: PMPG STA, BELOW DECK, BLDG. 7420, NBK-BANGOR 1391 REQUIRED: YES FOR CONSTRUCTION PACKAGE REQUIREMENT: This Service Request tasking is to design a fire protection system for the Bangor Dry-dock, Pump-well, B7424, to include UFC 3-600-1 compliant sprinkler systems, alarm systems, and smoke evacuation systems in the Pump-well as per recommende4d within the listed survey report referenced below. Design shall also include structural modifications and meet emergency egress requirements. It is expected that these designs will support follow-on Sustainment, Restoration and Modernization Program Projects, tentatively planned for FY25 at the earliest. BACKGROUND: The April 2021 PSNS&IMF Fire Protection Engineering Surveys Report, Trident Refit Facility, Bangor, identified fire protection deficiencies in the Bangor Dry-dock Pump-well, B7424. The Pump-well is classified as multi-story below-grade building requiring fire protection. The Pump-well is a special purpose industrial occupancy and is not equipped with fire sprinkler, fire alarm or smoke exhaust systems. The building houses the main dewatering pumps, drainage pumps, controls and electrical substations that are essential for dry-dock operations and lack emergency occupant egress openings. JUSTIFICATION: Life Safety Compliance NOTES (References): 1. 1391 Required-YES, for Construction Package 2. PSNS&IMF Fire Protection Engineering Survey Report (FPESR), Trident Refit Facility, Bangor 01 Apr 21 -- N44255-16-D-2006, Work Order 1664197 (NOTKIN/P2S). • FPESR is CUI and can be obtained by ... NOTE: description has been truncated, please see Project Note for full description.

More opportunities from Department Of The Navy → Navfac Northwest

Same awarding agency