Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM ET

Register Free →

24344488, Crane Rail & Structural Column #J-13, B873, PSNS

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This project involves the repair and structural support of crane rail and structural column J-13 within Building 873 at PSNS, managed by Navfac Northwest. The facility, a reinforced concrete structure built in 1977, currently faces critical access issues regarding chemical tubs on the North and West sides. Failure to restore full bridge crane access threatens the electroplating capabilities of S31 and S71, which could force operations to other installations and cause significant delays in the undocking schedules of multiple submarines and a carrier. The project is categorized as a CAT-2 / DBB-AE deliverable with design scheduled for the first quarter of fiscal year 2025 and construction slated for the first quarter of fiscal year 2026. Technical challenges include the building's original construction using working stress design rather than modern limit states methodology. The work is prioritized due to its direct impact on mission support and has received high-level attention to ensure the continued operational readiness of naval assets.

General Info

Repair crane rail and column J-13 at PSNS Building 873 to maintain operations.

NAICS

238120 - Structural Steel and Precast Concrete Contractors

Place of Performance

NW: BREM PDC, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
*DELIVERABLE: CAT-2 / DBB-AE * Design FY25/Q1 * Construction FY26/Q1 *MND: 8-1-2024 *Justification Statement: The inability to access the chemical tubs on the North and West side of B873 will affect S31 and S71's electroplating ability to support the mission. If the mobile cranes currently being used temporarily are unable to support, this will force the electroplating operations out to other installations, causing major delays that could impact the ships abilities to undock on time. Full bridge crane access to the chemical tubs will be critical to the avails of multiple submarines and a carrier. This has the attention of CAPT Crinklaw due to the mission support impacts. BACKGROUND: Building 873, completed in 1977, is a reinforced concrete structure composed of pre-cast tilt-up-panels, bearing wall perimeter and an interior of cast-in-place reinforced concrete columns. Structural steel is used in crane rails and crane support columns as well as structural mezzanines and floor grating support. The roof system is composed of pre-cast, pre-stressed structural tees, resting on a poured concrete ridge beam with poured concrete infill between the tees. Concrete design methodology at the time of construction was working stress design as opposed to the limit states methodology currently in use. Building 873, previously held the designation, Metal Fabrication Facility P/432. The construction of P/432 required the demolition of Building 145 and Building 538 on the site. The primarily level site did not contain utilities that were abandoned in place in the area adjacent to or near to column J-13. The grading plan indicates that the subject column and adjacent slab were not placed in an area of substantial fill. Column J-13 bears the load of approximately 25% of th ... NOTE: description has been truncated, please see Project Note for full description.

Similar Contracts

Same NAICS industry code

NAICS: 238120
New
Federal
Airfield Blast Shield
Solicitation # FA466126R0008
Solicitation FA466126R0008 is a 100% Small Business Set-Aside Invitation for Bid for the fabrication and erection of new blast deflector fences for B1-B bombers at Dyess Air Force Base, Texas. The project, estimated between 1 million and 5 million dollars, requires the installation of curved, non-perforated, galvanized, corrugated steel deflectors capable of withstanding 30,000 lbs of thrust at temperatures of approximately 1400 degrees Fahrenheit and velocities of 900 MPH. The Lynnco Type GS-20-2 is the established standard for this work. The scope includes providing all labor, equipment, and materials, with a requirement for the contractor to adhere to the International Building Code, National Fire Codes, and Unified Facilities Criteria. The contract is structured with a Base Bid for five deflectors to be completed within 60 calendar days of the Notice to Proceed, and an Option 1 for two additional deflectors to be completed within 14 calendar days. Award will be based on the Lowest Price Technically Acceptable (LPTA) approach, evaluating technical proposals on an acceptable or unacceptable basis regarding the schedule and technical methodology. Contractors must utilize the Wide Area WorkFlow system for invoicing and comply with Davis-Bacon Act wage determinations. Work is located in a restricted area, requiring strict adherence to approved haul routes, secure storage in a designated laydown yard, and the submission of crew schedules for escorts.
FA4661 7 Cons Cd

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 238120
New
SLED
ADF&G Request for Information (RFI) - Creamers Field Barn Column Stabilization and Repair
Solicitation # 225514
The State of Alaska Department of Fish and Game is issuing a Request for Information (RFI) for the stabilization and repair of steel support columns at the Creamers Field Barn in Fairbanks, Alaska. The project focuses on the evaluation and repair of 4 inch and 6 inch steel support columns located in the East, West, and Pole barns. Qualified contractors are expected to perform visual and ultrasonic testing to assess structural integrity and section loss, replace deteriorated columns with structural steel pipe columns of the same diameter, and prepare and paint all remaining columns black. Because the site is listed on the National Register of Historic Places, the contractor must coordinate efforts with the Department of Fish and Game and the State Historic Preservation Office. Due to the presence of hazardous materials including asbestos, lead paint, and PCBs, the contractor must comply with all state and federal regulations and submit an OSHA-compliant work plan detailing safe work practices and exposure limits. The project is guided by the 2022 Condition Assessment and Maintenance Plan by Design Alaska. This RFI is for information gathering purposes and does not obligate the state to a purchase. Interested parties must submit a response by October 20, 2026, at 2:00 PM AKST to dfg.contracting@alaska.gov, stating their capability to perform the scope of work and their willingness to participate in a future competitive solicitation.
Fish and Game

POSTED

1 day ago

DEADLINE

in 6 days
View Details

More opportunities from Department Of The Navy → Navfac Northwest

Same awarding agency

NAICS: 236220
Federal
MSR #23207821_1787796 -- (23207821) Repair Crane Track and Tunnel Arch Support DD1, PSNSThis project involves comprehensive seismic upgrades to the superstructure and substructure of a facility managed by Navfac Northwest, specifically focusing on the repair of crane tracks and tunnel arch support. The scope of work includes retrofitting building brace connections, modifying restrooms for American Barrier Act compliance, and updating heating and ventilation systems. Additionally, the project requires the removal and reinstallation of various architectural, electrical, and mechanical interferences, including plant equipment, shop tools, and storage racks. Electrical upgrades will be implemented to install a 480VAC three-phase grounded system and correct documented HDA safety hazard deficiencies across RAC 2, 3, and 4 categories. All work must comply with the Unified Facility Code, National Fire Protection Association, and International Building Code, while prioritizing energy efficiency and low life cycle costs. Because the machine shop is on the historical register, all modifications require review and concurrence from the State Historical Preservation Office to maintain the building's historical integrity. Station support will be provided through red badge escorts, outage coordination, hazardous material handling assistance, and a facility production process specialist to ensure seamless project execution.
Commercial and Institutional Building Construction

POSTED

3 months ago

DEADLINE

N/A
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS