CF26 NIWC Install Conduit between manhole 1.2.7 and VIDS RCU
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac WashingtonView Agency
NAICS
N/A
Place of Performance
USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Washington
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
Provide underground conduit between manhole 1.2.7 and VIDS RCU enclosure. Determine the shortest route and trench to the required depth. Install 4” PVC conduit ensuring watertight seal and backfill. At RCU location, provide weatherproof enclosure to house fiber panel and install stainless steel stanchions to support enclosure. IMPACT: Installation of new AN/FYC-22 Visual Information Display System (VIDS) equipment requires fiber connection to Remote Control Unit (RCU) used to activate NAWCPAD lighting. The Air Traffic Control Tower (ATCT) will not be able to control NAWCPAD lights if the project is not completed.