Repair and Increase Capacity of SOD System for Olympic Pier at B7042 and B7113, Bangor

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac NorthwestView Agency

NAICS

N/A

Place of Performance

NW: BANGOR PDC, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Northwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
PROJECT CHANGED FROM CAT-3 TO CAT-2. Deliverable pending. For B7113 Replace the oil and water separator to increase capacity to be able to support vessels being serviced at Olympic Pier: 7113-0-000-1534-20-1B. Replace electrical and computer paneling. new panel should be relocated on a raised platform from the concrete flooring to prevent water intrusion when flooding occurs. : 7113-0-000-160A-31-1A. Install a belt skimmer to the holding tank for contaminated water: 7113-0-000-1534-20-1A Clean and paint holding tank. Reactivate and paint oil tank: 7113-0-000-1620-40-1A. Provide ICS support for the alarm systems. Replace Sump Pumps All associated sensors and alarms. All associated electrical components. All associated backflow preventers and plumbing. For B7042 Replace Industrial Waste Pumps: 7042-0-103-1534-20-1A; 7042-0-103-1534-20-1B Replace Alarm System: 7042-0-104-1672-60-1A Replace sump pumps: 7042-0-000-1534-11-1C; 7042-0-000-1534-11-1D All associated electrical components, controls, sensors and alarms not listed. Justification: Olympic Pier increased its capacity to provide services for increased number of vessels. SOD system is showing increased number of leaks due to failed sensors.