Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

(20216368)(DBB-AE)(M2) Replace HVAC System, NDTIB, B/6593, SWFPAC

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac NorthwestView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Northwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
FY22/Q2 CAT 2 IH-DB Requirement: Design/Build: Replace the existing HVAC system. Replace air handling units with direct drive variable frequency drive (VFDs) and sealed bearings, dehumidifiers, humidifiers, boilers, chillers, hot and chill water pumps, process water pumps, exhaust fans, fan coil units, variable air volume (VAVs), water treatment for chilled and heating water systems, replace piping and all circuit setters, panelboards, motor control units, auxiliary heating coils, monitoring systems, and unit heaters. Install Direct Digital Controls (DDC), associated cabinets and program components. Dispose of old material. Ensure proper system operation. Ensure modifications are made to include the BOSC contract maintenance. Consider existing equipment listed below. Justification: Reliability is degraded. Most equipment has exceeded life expectancy. The current equipment cannot meet the environmental demands required. EQUIPMENT: 6593*0*106*1560*30*2A, HEAT GENERATION, ELECTRIC RESISTANCE HEATER 6593*0*106*1560*30*2B, HEAT GENERATION, ELECTRIC RESISTANCE HEATER 6593*0*106*1560*30*2C, HEAT GENERATION, ELECTRIC RESISTANCE HEATER 6593*0*106*1560*30*2D, HEAT GENERATION, ELECTRIC RESISTANCE HEATER 6593*0*106*1590*10*1D, Central Monitoring and Control, Condition Monitoring System 6593*0*ROF*1580*31*01, FAN, EXHAUST (EF-1) 6593-0-105-154A-12-1E, COMPRESSED AIR DISTRIBUTION, SERVICE AIR STATION 6593-0-106-154A-12-1C, COMPRESSED AIR DISTRIBUTION, SERVICE AIR STATION 6593-0-106-154A-12-1D, COMPRESSED AIR DISTRIBUTION, SERVICE AIR STATION 6593-0- ... NOTE: description has been truncated, please see Project Note for full description.