MSR#21206678_1726362 -- (21206678) PW5 MDP 2 Refurbishment to Include Motor, Pump, New Check Valve, and New Discharge Valve DD5, PSNS

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac NorthwestView Agency

NAICS

N/A

Place of Performance

NW: BREM PDC, USA

Set-Aside

SBA

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Northwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
FEAD DELIVERABLE: CAT2 CONTRACT PROGRAM YEAR: FY23 Q2 FUNDING SOURCE: ST SOW: Perform the work, for MDP-2 (Main Dewatering Pump-2: motor, pump and associated systems) that was not completed by SR 10235027. In addition to this, also replace MDP-2's discharge valve (including operator). Testing must be accomplish during a docking event. Testing shall include a duration test and capacity test. Water tight boundaries must be made water tight at least one week ahead of any docking even utilizing PW5 (unless specifically authorized by C980S.4) History: SR 10235027 was to overhaul all the main dewatering pumps (MDPs) for pumpwell 5 but the contractor was only able to accomplish the overhaul on MDP-1 before the money expired at the end of 5 years. While accomplishing this overhaul and a similar overhaul at Pumpwell (PW) 4 and 2, it became apparent that while one MDP was down for overhaul this was the best time to replace it's associated check valve and discharge valve. Learning from this, the SY wants to overhaul the MDP and replace it's associated valves and operators of said valves.