Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Replace Air Handler Units, TTF #16, 18, and 46, Bldg. 2000, Bangor (DB-IH) (16582554)

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac NorthwestView Agency

NAICS

N/A

Place of Performance

NW: BANGOR PDC, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Northwest
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Northwest
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
DELIVERABLE: PRI4 CAT 2 DB/IH PSC CODE: Z2CZ – REPAIR OR ALTERATION OF OTHER EDUCATIONAL BUILDINGS FACILITIES– D30 - HVAC REQUESTED SCHEDULE: FY2025, Q2 LOCATION: Bldg. 2000, NBK-BANGOR REQUIREMENT – Replace Air Handler Units…, Bldg. 2000, NBK-Bangor **** THIS PROJECT WILL REQUIRE A 1391*** REQUIREMENT: Air Handler Units: 1. Replace existing Air Handling Units (AHU) #16, 18 and #46, with new; to include their respective (3) Return Fans (RF’s). New AHU and RF shall be made up of a “Fan Wall” system; and if possible, the Supply Fan and Return fan shall be contained in one single AHU. Recommend 2-inch insulated AHU walls complete with new integrated mixed air damper system. 2. At time of project completion, ensure that full mechanical, electrical and communicative integration into the facility, including but not limited to; Building Management System (BMS). All existing BMS features currently in the system shall be reconnected and fully-operational on the new AHU and RF system-projects. Ensure that VFD’s are tracking and being controlled properly, ensure that Mixed Air Damper systems are being controlled and are aligned and working properly, fully integrate the Smoke/duct Fire detectors, ensure that the static/duct pressure control inputs and switches are fully integrated and tracking properly with relation to fan speeds and damper positions. 3.Prior to start-up and system testing/verification, the system must have a load to allow these system to operate within acceptable limits, for an extended period-of time at various stages of operation. The Contractor (s)—both installing and facility maintenance personal shall provide a means to create this load. 4.The contractor shall show by demonstration in service that the system is fully-operational and is properly performing all intended functions. Perform start-up, programming, calibration, adjustments (per manufacturer’s standards) a

More opportunities from Department Of The Navy → Navfac Northwest

Same awarding agency